Test & Debug Flow - NAD M55 Service Manual

Digital music player
Hide thumbs Also See for M55:
Table of Contents

Advertisement

3. Test & debug flow
TEST
Check the AC Voltage
Power PCBA(110V or 220V)
YES
Switch on the Power PCBA
Is the DC Voltage
outputs OK?
(5V,3.3V,9V,12V,15V)
YES
Make sure the main PCBA don't
short on VCCs and switch it on.
Is 3.3V,1.8V and 2V DC
outputs normal on main
PCBA?
YES
Insert the upgrade disc to update
the FLASH memory code.
Update FLASH
successfully?
YES
A
NO
Replace power PCBA or
AC transformer.
NO
Repair or Replace Power PCBA
NO
Check the regulators or related diodes.
1. Check 27MHz system clock.
2. Check system reset circuit.
NO
3. Check FLASH R/W enable signal LOE#,WRLL.
4. Check servo related circuit.
5. Check FLASH Memory related circuit.
3-5

Advertisement

Table of Contents
loading

Table of Contents