Download Print this page
Samsung RFG297AB**/XAA Troubleshooting Manual

Samsung RFG297AB**/XAA Troubleshooting Manual

Advertisement

Quick Links

Models Covered:
RFG297AB**/XAA
NOTICE:
Parts Bulletin
Handle change 2-2011
NOTICE:
Parts Change
The interior lighting has been changed
from incandescent lighting to LED lighting.
The new parts are NOT interchangeable
with the old parts. See page 4
Self Diagnosis: Press both buttons (Energy
Saver– Lighting) simultaneously (No sound
when both buttons are pressed at the same
time) ‟til the display quits blinking and
beeps, 8-12 seconds, then release and read
Fault Codes.
This will also cancel the Fault Mode created
by self-diagnosis at power up.
3600RPM
Press Freezer button one
time at the Test Mode to
Force Compressor High
Speed Run, measure fan
and Compressor volt-
ages at main PCB
Sales Mode, No Compressor Operation: Press Energy Saver & Freezer temp buttons simultaneously for 3 sec
( you will hear a "Ding Dong") to remove or put into Sales Mode. When in the Sales Mode the Display will show
"OF" "OF": Removing power will not cancel this mode.
Sealed System
SUPPORT INFORMATION
Training — Plus One
http://my.plus1solutions.net/clientPortals/samsung/
Help — GSPN
http://service.samsungportal.com/
Samsung Product Support TV
Customer information videos and chat programs. Programs for Fridges, Laundry, Ranges & D/W
# tsRFG297AB RevC 03/30/2011
Fast Track Troubleshooting
Publication # tsRFG297AB Revision Date 03/30/2011
IMPORTANT SAFETY NOTICE – "For Technicians Only" This service data sheet is
intended for use by persons having electrical, electronic, and mechanical experience
and knowledge at a level generally considered acceptable in the appliance repair trade.
Any attempt to repair a major appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible, nor assume any liability for
injury or damage of any kind arising from the use of this data sheet.
Forced Mode: Press both buttons (Energy Saver– Fridge) simulta-
neously (No sound when both buttons are pressed at the same
time) „til it beeps and goes blank, 8-12 seconds
2450RPM
Press Freezer button a
second time to Force
Mid Speed Run
Refrigerant Charge
R134a
5.64 oz.
http://support-us.samsung.com/spstv/howto.jsp
2200RPM
Wait 5 seconds between button pushes
Press Freezer button a
third time to Force Low
Speed Run
Component Value Chart
Component
Resistance Wattage Voltage
Freezer Defrost Heater
Fridge Defrost Heater
French Mullion Heater
Ice Duct Heater
Dispenser Heater
Water Tank Heater
Sensors
2.5kΩ-89kΩ
Fans
Press Freezer button a
forth time to Force De-
frost of Fridge & Freezer,
measure defrost voltage
at main PCB
60Ω
240
120vac
120Ω
120
120vac
1800Ω
8
120vac
3600Ω
4
120vac
7200Ω
2
120vac
72Ω
2
12vdc
N/A
1~4.5vdc
N/A
N/A
7~12vdc
1

Advertisement

loading

Summary of Contents for Samsung RFG297AB**/XAA

  • Page 1 2.5kΩ-89kΩ 1~4.5vdc R134a 5.64 oz. Fans 7~12vdc SUPPORT INFORMATION Training — Plus One http://my.plus1solutions.net/clientPortals/samsung/ Help — GSPN http://service.samsungportal.com/ Samsung Product Support TV http://support-us.samsung.com/spstv/howto.jsp Customer information videos and chat programs. Programs for Fridges, Laundry, Ranges & D/W # tsRFG297AB RevC 03/30/2011...
  • Page 2 -14 degrees Fahrenheit. Selecting "Ice Off” will allow the freezer to be controlled by the set tem- perature. If water is not hooked up, the freezer will always be at –14 unless “Ice Off” is selected. Temperature/Resistance/Voltage Chart for Samsung Refrigerators Sensors Temp.
  • Page 3 Samsung 'Refrigerator' Diagnostic Code Quick Guide Error Items TROUBLE TESTING I/M-SENSOR (R on Ice Maker Sensor Error- open or short-circuit, connector failure. The voltage at MAIN PCB Twin I/M units) Cause is also a temperature reading > 122°or < -58 ° F Sensor between 4.5V~1.0V...
  • Page 4 SERVICE BULLETIN PRODUCT: Refrigerator BULLETIN NUMBER: ASC20100714001 DATE: 07/14/2010 Please review before ordering any parts. CN78 CN71 All 120vac 1-3 Fz LED (Blk-Gry) 5-N (Gry) 4-7-FF LED (Red-Gry) 9-Def Htr Common (Org) # tsRFG297AB RevC 03/30/2011...
  • Page 5 7 F Fan FG(Brn) 11- N (Gry) 8 R Fan FG(Red) 9 C Fan FG(Blu) CN30 Sensors & Switches RFG297AB**/XAA 1-5 Freezer Dr Sw (Blk-Gry) 5vdc 2-(CN50-7) R Door Sw (Prp-Gry) 5vdc (early production) 3-(CN76-1) F Sensor (Red-Gry) 3.5~4.2vdc 4-(CN76-1) F Def Sensor (Org-Gry) 2.3~4.2vdc 6-(CN76-1) R Sensor (Wht-Gry) 2.4~2.8vdc...
  • Page 6 = New Production Change # tsRFG297AB RevC 03/30/2011...
  • Page 7 Compressor & System Operation Testing The Time Divided Multi-cycle (TDM) System (Stepper Valve) is used to switch refrigerant flow . This improves temperature control and energy efficiency. If it fails in the all evaporator mode, it should work properly, using slightly more energy.