Download Print this page

Crown IQ-RPT 3 Supplementary Manual

Crown iq-rpt 3 repeaters: supplementary guide

Advertisement

Quick Links

IQ-RPT 3
T
he Crown IQ-RPT 3 repeater helps an IQ
System go the extra distance by increas-
ing the length of an IQ Bus loop. It does
this by reconstructing the data signal to prevent
its degradation. With an IQ-RPT 3 in a system,
1,000 feet (305 m) or more can typically be
added to the operating distance of an IQ Bus.
And because more than one IQ-RPT 3 can be
used on each IQ Bus loop, the potential is
impressive.
The IQ-RPT 3 works with any IQ interface,
including both IQ and IQ
legacy interfaces.
2
Plus, the IQ-RPT 3 is backed by Crown's
unequaled Three-Year, No-Fault, Fully Transfer-
rable Warranty that covers everything.
For more details about the Crown IQ-RPT 3,
contact the Crown Technical Support Group at
800-342-6939 or 219-294-8200. Also, visit the
Crown Audio website at www.crownaudio.com.

Specifications

General
Connectors: IQ Bus Input: RJ-45 connector.
IQ Bus Output: RJ-45 connector. AC Power:
IEC320 connector for AC power cord. All con-
nectors are located on the rear panel.
Indicators: Blue front and rear panel Power
indicators show that the unit is plugged in
and receiving power. Yellow front and rear
panel indicators show loop send data activity.
Green front and rear panel indicators show loop
receive data activity.
Power Supply: Universal input switching power
supply.
R E P E A T E R
Features
• Increases the length of an IQ Bus loop by as
much as 1000 feet (305 m).
• Blue Power indicators on the front and rear
panels.
• Yellow Send and green Receive indicators on
the front and rear panels show IQ Bus loop
data activity.
Power Requirements: 100VAC to 240VAC, 47
Hz to 66 Hz.
Power Consumption:
60 Hz
50 Hz
100VAC
3.70W
3.71W
120VAC
3.92W
3.92W
220VAC
5.03W
5.03W
230VAC
5.23W
5.18W
240VAC
5.59W
5.41W
Crown Bus Data Communication
Protection: The auto-reset feature is controlled
by the microprocessor. Optically coupled
20-milliamp current loop receivers provide
ground isolation.
Data Rate: 38.4 K baud.
Data Format: Asynchronous binary serial data
with 1 start bit, 1 stop bit, 8 data bits and no
parity check.
Interface Type: 20-milliamp current loop.
Operation: Half duplex.
• RJ-45 connectors for IQ Bus input and output
for easy and secure IQ Bus connections.
• Supports both the original IQ and newer IQ
protocols.
• Three-Year, No-Fault, Fully-Transferable
Warranty protects your investment and
guarantees the specifications.
Intelligence: 16-bit microprocessor.
Transmission Distance: Variable from 200 to
3,000 feet (61 to 914 meters) depending on
wire capacitance.* 1,000 feet (305 meters) is
typical with shielded 26 AWG twisted pair wire.
More IQ repeaters or fiber optic transceivers
can be used to cover greater distances.
Mechanical
Finish: Charcoal powder-coated steel chassis
and front panel with Lexan
front and rear over-
®
lays.
Dimensions: 19-inch (48.3 cm) standard rack
mount width (EIA RS-310-B), 1.75-inch (4.4
cm) height and 6.5-inch (16.5 cm) depth.
Weight: 6 lbs., 4 oz (2.8 kg) net; 9 lbs., 5 oz
(4.2 kg) shipping.
*Maximum IQ Loop capacitance should be approximately
30nf. Add 60pf of capacitance for every IQ component in the
IQ Loop for the calculation of loop capacitance.
2

Advertisement

loading

Summary of Contents for Crown IQ-RPT 3

  • Page 1: Specifications

    IQ Bus loop. It does this by reconstructing the data signal to prevent its degradation. With an IQ-RPT 3 in a system, 1,000 feet (305 m) or more can typically be added to the operating distance of an IQ Bus.
  • Page 2 With this unprecedented No-Fault protection, your new Crown IQ component is warranted to meet or exceed original specifications for the first three years of ownership. During this time, if your IQ component fails, or does not perform to original specifications, it will be repaired or replaced at our expense.