Pump; Function; Checks; Removal Pump - Biasi RIVA PLUS HE 24C ERP Service Manual

Combi boiler
Hide thumbs Also See for RIVA PLUS HE 24C ERP:
Table of Contents

Advertisement

8

PUMP

8 .1 Function

The pump A in Figure 8.1 and Figure 8.3 has the function of mak-
ing the water in the main circuit circulate through the main heat
exchanger, the condensing heat exchanger and therefore through
the c.h. system (during the c.h. function) or through the secondary
heat exchanger (during the d.h.w. function).
Figure 8 .1

8 .2 Checks

Warning: isolate the boiler from the mains electricity
supply before removing any covering or component .
Check that the pump is not seized and that the movement of
the rotor is not subject to mechanical impediments.
The pump doesn't need.
Switch the boiler on.
The electronic control circuit provides automatically to unlock the
pump to avoid seizing.
There is no inspection plug and it's not necessary to operate man-
ually with screwdriver.
Check that the impeller is integral with the rotor.
With the boiler off remove the front and right hand side case pan-
els, lower the control panel and empty the primary circuit.
Remove the pump head by undoing the screws which hold it to
the pump body and check that the impeller is firmly joined to the
rotor.

8 .3 Removal pump

Warning: isolate the boiler from the mains electricity
supply before removing any covering or component .
- 16 -
PUMP
A
1 Remove the case panels and the sealed chamber lid (section
"Body panels" page 5).
2 Empty the primary circuit of the boiler.
3 Disconnect the connector B (Figure 8.3).
4 Loosen the connection D (Figure 8.2),and pull up and turn to
the left the pipe E.
5 Remove the locking plate F (Figure 8.3).
Figure 8 .2
B
A
Figure 8 .3
7 Unscrew the two screws G that hold the pump on the frame
and remove the pump.
Reassemble the pump carrying out the removal operations in the
reverse order. When reassembling the pump, check the correct
location of the O-ring gasket in the inlet port of the pump that seals
the connection between the pump and the return water group.
C
E
D
F
G

Advertisement

Table of Contents
loading

This manual is also suitable for:

Riva plus he 28c erp

Table of Contents