To obtain the latest version of this manual, please visit the Crown website at www.crownaudio.com. Trademark Notice: PIP and IQwic are trademarks, and Amcron, Crown, Crown Audio, Macro-Tech, IOC, IQ System, VZ and ODEP are registered trademarks of Crown International. Other trademarks are the property of their respective owners.
Macro-Tech MA-3600VZ Power Amplifier Important Safety Instructions Read these instructions. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE Keep these instructions. TOP OR BOTTOM COVERS. NO USER SERVICE- Heed all warnings. ABLE PARTS INSIDE. REFER SERVICING TO Follow all instructions. QUALIFIED SERVICE PERSONNEL.
Macro-Tech MA-3600VZ Power Amplifier DECLARATION of CONFORMITY Crown International, Inc. TCF Technical Certificate No: P4300CRI1.IWS Technical Construction File Route Sue Whitfield Issued By: Crown International, Inc. 574-294-8289 1718 W. Mishawaka Road swhitfield@crownintl.com Elkhart, Indiana 46517 U.S.A. Competent Body’s Name and Address:...
8.2.2 Factory Service ................. 21 4.2 Front Panel Controls and Indicators ..............12 8.2.3 Factory Service Shipping Instructions ........21 4.3 Back Panel Controls and Connectors .............13 9 Warranty ..............22 Crown Factory Service Information Form ............25 page 4 Operation Manual...
In addition, the MA-3600VZ amplifier includes a number of features which require some expla- nation before they can be used to their maxi- mum advantage.
The side walls of turned completely down (counterclock- the rack should be a minimum of two inches initiate a claim for shipping damage. Crown (5.1 cm) away from the amplifier sides, and the will be happy to help as needed. Save the ship- wise).
Macro-Tech MA-3600VZ Power Amplifier 3 Setup Unbalanced Line 3.4 Choose Input Wire Balanced Line and Connectors Figure 3.3 shows connector pin assignments for balanced wiring, and Figure 3.4 shows connec- tor pin assignments for unbalanced wiring. NOTE: Custom wiring should only be performed by qualified personnel.
Figure 3.5 Output Connector Wiring fore be used. (MA-3600VZ Has 4 Pairs of Posts. Only 2 Pairs Are Shown.) Using the guidelines below, select the appropri- ate size of wire based on the distance from amplifier to speaker.
Macro-Tech MA-3600VZ Power Amplifier 3 Setup 3.6 Wire Your System 3.6.1 Stereo Mode Typical input and output wiring is shown in Figure 3.6. INPUTS: Connect input wiring for each channel. Refer to Section 3.4 for input connector pin assignments. OUTPUTS: Maintain proper polarity (+/-) on output connectors.
NOTE: Remove the jumper wire before changing to any mode except Parallel- Mono. NOTE: Crown provides a reference of wiring pin assignments for commonly used connector types in the Crown Amplifier Application Guide available at www.crownaudio.com.
This may Use the following procedure when first turning Remember: Crown is not liable for damage that form a ground loop and cause oscillations. on your amplifier: results from overdriving other system components.
Macro-Tech MA-3600VZ Power Amplifier 4 Operation energy reserves decrease. In the event that 4.2 Front Panel Controls C. Signal/IOC Indicator energy reserves are depleted, the indica- and Indicators Green LED, one per channel. Tri-purpose tors turn off and ODEP limiting occurs.
Macro-Tech MA-3600VZ Power Amplifier 4 Operation Input Sensitivity Switch 4.3 Back Panel Controls M. XLR Inputs (Standard PIP Module) and Connectors One per channel, female XLR input con- Located behind the PIP module is the Input nectors are provided. Sensitivity switch. See Section 5.3.3 for G.
5.2.2 Variable Impedance (VZ) Protection (ODEP) distortion of 0.05% or more. An IOC condition VZ is the name of Crown's patented articulated may also be sensed by an IQ PIP module Crown invented ODEP to solve two long stand- power supply technology. This innovative tech- installed in PIP-compatible amplifiers.
5.3.3 Input Sensitivity Switch jacks. The signal grounds are not paralleled. For exam- via Crown’s SmartAmp™ IQ features set, plus a wide The Input Sensitivity Switch is located inside the back of ple, XLR pins 2 and 3 are connected in parallel with the range of digital signal processing capabilities.
Macro-Tech MA-3600VZ Power Amplifier 6 Specifications Minimum Guaranteed Power 120VAC, 60 Hz Units 100VAC International 120 VAC International 230VAC International (see page 18 for complete power specifications) Units Units Units Power in watts per channel,1 kHz, 0.1% THD Stereo mode with both channels driven...
Page 17
Macro-Tech MA-3600VZ Power Amplifier 6 Specifications Performance (continued) Output Impedance See Figure 6.5 Load Impedance (Note: Safe with all types of loads) 2-8 ohms Stereo 4-8 ohms Bridge Mono 1-2 ohms Parallel Mono Voltage Gain (8-ohm load, rated output at 1 kHz, maximum level setting) 124.6:1 ±6% or 41.9 dB ±0.5 dB...
Page 18
Macro-Tech MA-3600VZ Power Amplifier 6 Specifications Figure 6.1 Minimum Power Matrix Figure 6.2 Maximum Power Matrix page 18 Operation Manual...
Page 19
Macro-Tech MA-3600VZ Power Amplifier 6 Specifications Figure 6.6 Typical Figure 6.3 Typical Phase Response Frequency Response –1 8 ohm 1 watt 4 ohm –2 2 ohm –3 +45˚ –4 –5 0˚ –6 –7 10 K 100 K –45˚ FREQUENCY (Hz) Figure 6.4 Typical...
• This is normal operation for your amp. • The amplifier's low-voltage power supply fuse has blown. Return amp to Crown or an authorized Crown Service Center for servicing. • The amp is set for Parallel Mono mode. CONDITION: No sound.
Refer servicing to a quali- mentation, cables and other hardware. cost of shipping, and Crown will reimburse you. fied technician. Send copies of the shipping receipts to Crown to If you have any questions, please call or write receive reimbursement. 8.1 Worldwide Service the Crown Technical Support Group.
Crown ITEMS EXCLUDED FROM THIS eign country and the port of entry in the United CROWN WARRANTY product.
Page 23