The 120 Volt 60 Hz version, sold in the United States,
is not voltage selectable. It does not have voltage
selection boards. This version is to be used only with
120 Volts, 60Hz.
Jumpers
Circuit Breakers
CB100/CB200
Fuse
F1
Transmotor
TF1
Macro-Tech 2400 Amplifier Service Manual
Voltage Conversion
All other versions of the Macro Tech 2400 use voltage
selection boards. The following chart indicates which
jumpers are used for different voltages. Note that the
fuses and transmotor may need to be changed to
accommodate different voltages. Versions with the
voltage selection boards may be used at 50 or 60 Hz.
VOLTAGE SELECTION BOARD
120V
100V
ORG—B
ORG—A
B—E
A—D
BLU—F
BLU—F
C—F
C—F
C10169-8
15 Amp
A10285-10
1 Amp
H42999-5
H42929-2
200V
220V/230V
ORG—B
ORG—B
C—D
C—E
BLU—F
BLU—F
C10171-4
8 Amp
A10285-7
.5 Amp
H42928-4
240V
ORG—A
C—D
BLU—F
7