Voltage Conversion - Crown 1200 Service Manual

Crown micro-tech -1200 power amplifier service manual
Hide thumbs Also See for 1200:
Table of Contents

Advertisement

The 120 Volt 60 Hz version, sold in the United States,
is not voltage selectable. It does not have voltage
selection boards. This version is to be used only with
120 Volts and only with 60Hz.
All other versions of the Micro Tech 1200 use voltage
selection boards. The following chart indicates which
jumpers are used for different voltages. Note that the
fuses and transmotor may need to be changed to
accommodate different voltages. Versions with the
voltage selection boards may be used at 50 or 60 Hz.
Jumpers
Fuses
F100/F200
Transmotor
TF1
Micro-Tech 1200 Amplifier Service Manual

Voltage Conversion

VOLTAGE SELECTION BOARD
120V
100V
Z100
Z101
Z104
Z104
Z106
Z105
Z201
Z200
Z204
Z204
Z206
Z205
A10285-28, 20A
H43068-8
H43407-8
200V
220V/230V
Z101
Z101
Z102
Z103
Z201
Z201
Z202
Z203
A10285-26, 10A
H43061-3
240V
Z100
Z102
Z200
Z202
7