Safety Features

• Overheat: The appliance will automatically shut
down when the appliance exceeds a predetermined
temperature.
• Flame Failure: The appliance will automatically
shut down if the burner flame is extinguished.
• Power Failure: The appliance will cut off the gas if
it loses electrical power.

Appliance Specifications

Application
General Description
Operation
Gas Connection
Gas Control
Burners
Temperature Control
Ignition System
Flue System
Humidifier Tray
Electrical Connection
Weight
Noise Level
AFUE Rating
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating
conditions and was determined independently of any installed system.
4
• Power Surge Fuse: A glass fuse on the PC board
• Spark Detector: The appliance automatically shuts
• Fusible Link: In case the overheat feature

Specifications

For manufactured home (USA only) or mobile home or residential
installation convertible for use with natural gas and liquefied petroleum
gases when provision is made for the simple conversion from one gas to
the other.
For commercial installations.
For installation at altitudes up to 10,200 feet (3109 m).
Forced combustion, forced convection, flued gas furnace
Push button electronic
1/2 in female NPT
Electronic
Stainless steel Bunsen burner
Electronic thermostat
Electronic spark ignition
The flue must be terminated to atmosphere with only flue components listed
with the appliance's certification. Warranty will be voided if non listed
components are installed.
Capacity - 1.5 pints (700 cc)
AC 120V, 60 Hz, 42 watts
39.4 lbs (17.9 kg)
27-34 dB
Natural Gas: 80.6%
Rinnai Corporation ES08 Manual
protects against overcurrent. If the fuse blows then
all indicator lamps will be off.
down if there is an abnormal spark at ignition.
prevents the temperature from rising then the fusible
link will break shutting off the appliance.
Propane: 83.4%