Rinnai ES08 Owner's Operation And Installation Manual

Rinnai ES08 Owner's Operation And Installation Manual

Energysaver gas direct vent wall furnace
Hide thumbs Also See for ES08:

Advertisement

Owner's Operation and Installation Manual for the
ES08 (RHFE-201RFA)
Gas Direct Vent Wall Furnace
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Register your product at www.rinnairegistration.com
or call 1-866-RINNAI1 (746-6241)
Energysaver
Table of Contents ........... 2
Safety Information........... 3
Fault Codes .................... 13
Consumer Support .......... 36

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai ES08

  • Page 1: Table Of Contents

    Owner’s Operation and Installation Manual for the ES08 (RHFE-201RFA) Energysaver Gas Direct Vent Wall Furnace Table of Contents ... 2 Safety Information... 3 Operating Instructions ..6 Care and Maintenance ... 10 Fault Codes ....13 Installation Instructions ... 14 Consumer Support ..
  • Page 2: Table Of Contents

    Flue Manifolds ..........5 Flue Manifold Installation ....20, 21 Connecting the Appliance ......22 Operating Instructions Operating Instructions ......23 Getting to Know your ES08 ......6 Cut-Away Diagram ........24 Control Panel ..........7 Wiring Diagram ......... 25 Operating Information Ladder Diagram ........
  • Page 3: Safety Information

    • Clothing or other flammable material should not be placed on or near the appliance. • Any safety screen or guard removed for servicing must be replaced prior to operating the appliance. Rinnai Corporation ES08 Manual...
  • Page 4: Safety Features

    AFUE Rating Natural Gas: 80.6% Propane: 83.4% Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.
  • Page 5: Features

    9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Rinnai Corporation ES08 Manual...
  • Page 6: Operating Instructions

    Operating Instructions Getting to know your new ES08 Rinnai Corporation ES08 Manual...
  • Page 7: Control Panel

    Control Panel All buttons beep when operated. Rinnai Corporation ES08 Manual...
  • Page 8: Operating Information

    After another 30 minutes the temperature setting is reduced another 2° F. This could result in the temperature setting being reduced by a maximum of 4° F. The intent of this mode is to save energy. Rinnai Corporation ES08 Manual...
  • Page 9: Function Lock

    Based on the information collected by the room temperature thermistor when the heating starts, the heating capacity is automatically adjusted to achieve a comfortable heating effect and to reach the temperature setting quickly. Rinnai Corporation ES08 Manual...
  • Page 10: Care And Maintenance

    The appliance will not function properly if the intake air or exhaust is impeded by obstructions. Yellow flames or Refer to the Flue Terminal Clearances. The clearance orange color in Ref. A should be maintained from any snow accumulation. Rinnai Corporation ES08 Manual...
  • Page 11: Before Making A Service Call

    High efficiency appliances tend to discharge water vapor on cold days. This is normal. Unit cuts off without apparent reason. Check whether filters are blocked. Dirty filters will cause the heater to overheat. Power Failure. Switch OFF, then ON again when power is restored to re-set controls. Rinnai Corporation ES08 Manual...
  • Page 12: Troubleshooting

    Flue manifold not connected Service Call Louver obstructed Clear obstruction Air filter blocked Clean filter Gas Escape Service Call Function Lock Set Cancel Function Lock Gas turned off at meter, tank, Turn gas on or valve. Rinnai Corporation ES08 Manual...
  • Page 13: Fault Codes

    If the fault code remains assist in diagnosing the problem. The fault code will or returns on the next operation, contact Rinnai or your flash in the display on the control panel. When making nearest service agent and arrange for a service call.
  • Page 14: Installation Instructions

    Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a • Rinnai suggests that a dedicated electrical circuit standard is not applicable, the standard for with a 120VAC, 60 hz, 10 amp power source be Manufactured Home Installations, ANSI/NCSBCS used.
  • Page 15: Gas Connection

    When determining where to install the appliance the clearances to combustibles shown in the figure must zero be followed. Also refer to the Safety Behaviors and Practices section. The clearance to combustibles from the top is zero. Rinnai Corporation ES08 Manual...
  • Page 16: Installation Parts

    The following items are included with the appliance. • Owner’s Operation and Installation Manual • Conversion Manual • Conversion Kit • “A” Vent Kit • Manual valve set, backspacers, screws, pipe stoppers, and hardware listed below Rinnai Corporation ES08 Manual...
  • Page 17: Drilling Flue Hole

    158 is used then do not use the template. The center center of the weatherboard from the outside first and of the wall opening will be 16 1/2 in (418.5 mm) above then through the plasterboard. A template is provided. the base of the appliance. Dimensions Rinnai Corporation ES08 Manual...
  • Page 18: Flue Terminal Clearances

    Flue Terminal Clearances Rinnai Corporation ES08 Manual...
  • Page 19 Flue Terminal Clearances Rinnai Corporation ES08 Manual...
  • Page 20: Flue Manifold Installation

    • This appliance can only be used with one of the five not exhaust into other rooms. types of Rinnai flue kits. The flue kits and their di- mensions are listed in the Specifications section. • The flue is not designed to be positioned under •...
  • Page 21 Push the assembly into the terminal tube, ensuring that the seal is in place on the inner tube. Attach the inside connection with 3 screws. The inner connection can still be turned to install the screws. 3 screws Rinnai Corporation ES08 Manual...
  • Page 22: Connecting The Appliance

    5. Install the bracket on the rear of the top spacer by tightening 2 screws. 6. Install the wall bracket with two screws. Install the top spacer by clipping the spacer into the wall brackets and attaching it to the heater with 2 screws. Rinnai Corporation ES08 Manual...
  • Page 23: Operating Instructions

    ON/OFF button. wall. Keep burner and control compartment clean. See installation and 3. Locate the manual gas valve on the side of operating instructions. the heater. Turn the manual valve clockwise to the full OFF position. Rinnai Corporation ES08 Manual...
  • Page 24: Cut-Away Diagram

    Cut-Away Diagram Rinnai Corporation ES08 Manual...
  • Page 25: Wiring Diagram

    Wiring Diagram Rinnai Corporation ES08 Manual...
  • Page 26: Ladder Diagram

    FLAME ROD CONVECTION FAN CONVECTION FAN MOTOR SPARKER OH. TH OVER HEAT THERMISTOR SV1~2 MAIN SOLENOID VALVE 1~2 COMBUSTION FAN MOTOR FAN CONTROL CIRCUIT CENTRAL PROCESSING UNIT MAIN BURNER PRESSURE SENSOR OHS1~2 OVER HEAT SWITCH 1~2 Rinnai Corporation ES08 Manual...
  • Page 27: Flow Diagram

    Flow Diagram Rinnai Corporation ES08 Manual...
  • Page 28: Parts List

    Parts List For replacement parts call Rinnai at 1-800-621-9419. Rinnai Corporation ES08 Manual...
  • Page 29 Parts List Rinnai Corporation ES08 Manual...
  • Page 30 Parts List Rinnai Corporation ES08 Manual...
  • Page 31 Parts List Rinnai Corporation ES08 Manual...
  • Page 32 Parts List Rinnai Corporation ES08 Manual...
  • Page 33 COMBUSTION CHAMBER FIXER 308F-214 HEAT EXCHANGER BRACKET 556F-135 SEAL PLATE 556F-131-2 FLANGE B 308F-205-2 BURNER BOX ASS'Y B3A2-4 BURNER ASS'Y 556F-225-2 BURNER SUPPORTER ASS'Y 556F-211 BURNER BOX PACKING 308F-209 PRIMARY DAMPER 308F-208 SECONDARY AIR DAMPER 556F-210-2 PACKING B Rinnai Corporation ES08 Manual...
  • Page 34 COMBUSTION FAN MOTOR ASS'Y 308F-8273 CUSHION RUBBER 308F-434 COMBUSTION FAN CASING ASS'Y 308F-232-2 CONVECTION FAN CASING B 308F-231 CONVECTION FAN 201F-2036 MOTOR BASE 201F-2037 CONVECTION MOTOR ASS'Y 201F-2037-2 CAPACITOR 308F-313 TF BRACKET 308F-325 OHS No.2 BRACKET Rinnai Corporation ES08 Manual...
  • Page 35 WATER LINE LABEL 431F-1830 EXHAUST CAUTION LABEL 431F-1862 GAS CHECK LABEL 431F-1863 GAS CHECK LABEL BRR37-244 ON-OFF VALVE ASS'Y 308F-2070-7 CONVERSION KIT(FOR NG) 308F-2070-8 CONVERSION KIT(FOR LPG) CP-74311-1 RATING PLATE SUPPORT LABEL CP-74312-1 RATING PLATE SUPPORT LABEL Rinnai Corporation ES08 Manual...
  • Page 36 CP-30421-1 SCREW ZAA0316SZ SCREW ZAA0422SZ SCREW ZBA0408SZ SCREW ZBB0410SC SCREW ZBD0408SZ SCREW ZDAA0410SZ SCREW ZEAB0406SC SCREW ZEAB0408SC SCREW ZEAB0408SZ SCREW ZEAB0408UK SCREW ZEDB0408SB SCREW ZEDB0408SZ SCREW ZEDB0410SZ SCREW ZEDB0412SZ SCREW ZHAA0406SZ SCREW ZHAA0410SZ SCREW CP-30486-2 SCREW Rinnai Corporation ES08 Manual...
  • Page 37: Consumer Support

    What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that is defective in materials or workmanship as set forth. Rinnai will pay reasonable labor charges associated with the repair or replacement of any such part or component.
  • Page 38 This Warranty does not apply to any product whose serial number or manufacture date has been defaced. Limitation on warranties No one is authorized to make any other warranties on behalf of Rinnai America Corporation. Except as expressly provided herein, there are no other warranties, expressed or implied, including, but not limited to warranties of...
  • Page 39 Notes Rinnai Corporation ES08 Manual...
  • Page 40 • Up to 83% AFUE Energy Efficiency • Zero-Clearance Installation • Available in Four Options of Fronts • Remotes and Fan Included • Gas Conversion Kit Available Hydronic Air Handler Designed for Use with Rinnai Systems • Domestic Hot Water Priority • • Optional Programmable Thermostat Zero Clearance to Combustibles •...

Table of Contents