ELECTRONIC CONTROL OPERATING INSTRUCTIONS
Before you begin, thoroughly familiarize yourself with the control panel and remote controller
and all its functions, then follow the symbols for the functions you desire.
The unit can be controlled by the unit control panel itself with the remote control .
NOTE: This manual does not include Remote Controller Operations, see the <<Remote
Controller Instruction>> packed with the unit for details.
OPERATION PANEL OF THE AIR CONDITIONER
(Only available on
models with auto-
swing feature)
AUTO
COOL
HEAT
DRY
FAN
Fig.4
MODE select button
1
Selects the operating mode. Each time
you press the button, the mode cycles through
the following sequence: AUTO, COOL, DRY,
FAN and HEAT(not available on cooling only
models). he mode indicator light illuminates
T
according to the mode selected. Fig.4.)
2
TIMER button
Used to initiate the AUTO ON start time and
AUTO OFF stop time program, in conjuction
with the
&
buttons.
3
POWER button
Power switch on/off.
SLEEP button
4
Used to initiate the SLEEP mode.
5
FAN button
Controls the fan speed. Press to select the fan
speed in four steps-LOW, MED, HI and AUTO.
The fan speed indicator light illuminates the
corresponding fan settings except AUTO . On
AUTO fan speed, all fan indicator lights will be off.
6
9
SWING
TIMER ON
MODE
TIMER OFF
2
1
(

AIR CONDITIONER FEATURES

7
6
F
C
3
UP(
) and DOWN(
6
Used to adjust (increasing/decreasing)
temperature settings(one degree increments)
in a range of 17 C(62 F) to 30 C(88 F) or
the TIMER setting.
NOTE: The control is capable of displaying
temperature in Fahrenheit or Celsius.
To convert from one to the other, press and
hold the Up and Down buttons at the same
time, for 3 seconds.
7
LED Display
Shows the set temperature in
O
F and the Auto-timer settings.
While on DRY and FAN modes, it shows
the room temperature.
Error codes and protection code:
E1- Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call for service.
P1- Bottom tray is full - Connect the
drain hose and empty the collected
water. If error repeats, call for service.