Table 7: Ratings & Physical / Electrical Data
Input - HI/LOW
Output - HI/LOW
MBH
kW
MBH
60/39
18/11
58/37
80/52
23/15
77/50
80/52
23/15
77/50
100/65
29/19
96/62
100/65
29/19
96/62
120/78
35/23
115/75
Max. Outlet Air Temp
°F
°C
HP
170
76.7
1/2
175
79.4
1/2
175
79.4
3/4
175
79.4
3/4
175
79.4
1
180
76.7
1
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
SUPPLY VOLTAGE CONNECTIONS
Junction
Box
Connect ground
lead to screw
Electrical Entry
L1-Hot
BLK
WHT
Neutral
FIGURE 17: Electrical Wiring
1. Provide a power supply separate from all other circuits. Install over-
current protection and disconnect switch per local/national electrical
codes. The switch should be close to the unit for convenience in
servicing. With the disconnect or fused switch in the OFF position,
check all wiring against the unit wiring label. Refer to the wiring dia-
gram in this instruction.
2. Remove the wiring box cover screws. Route all power wiring
through a conduit connector or other proper bushing that has been
installed into the unit opening and the junction box. In the junction
box there is a black wire, a white wire and a green ground screw.
Connect the power supply as shown on the unit's wiring label
located on the inside of the blower compartment door, or the wiring
schematic in this section. Connect the black wire to L1 (hot) from
the power supply. Connect the white wire to neutral. Connect the
ground wire (installer-supplied) to the green (equipment ground)
screw. An alternate wiring method is to use a field-provided 2" (5.1
cm) x 4" (10.2 cm) box and cover on the outside of the furnace.
Route the furnace leads into the box using a protective bushing
where the wires pass through the furnace panel. After making the
wiring connections replace the wiring box cover and screws. Refer
to Figure 17.
3. The furnace's control system requires correct polarity of the power
supply and a proper ground connection. Refer to Figure 17.
12
Nominal Air Flow
kW
CFM
17/11
1200
22/14
1200
22/14
1600
28/18
1600
28/18
2000
33/22
2000
Blower
Blower Size
Amps
in.
7
11 x 8
27.9 x 20.3
7
11 x 8
27.9 x 20.3
8.8
11 x 10
27.9 x 25.4
8.8
11 x 10
27.9 x 25.4
14.5
11 x 11
27.9 x 27.9
14.5
11 x 11
27.9 x 27.9
Total Unit
AFUE
m3/min
Amps
%
34
10
96
34
10
96
45.3
11.5
96
45.3
11.5
96
56.6
17
96
56.6
17
96
Max. Over Current
cm
Protect
15
15
15
15
20
20
The power connection leads and wiring box may be relocated to the
left side of the furnace. Remove the screws and cut wire tie holding
excess wiring. Reposition on the left side of the furnace and fasten
using holes provided.
LOW VOLTAGE CONTROL WIRING CONNECTIONS
Install the field-supplied thermostat by following the instructions that
come with the thermostat. With the thermostat set in the OFF position
and the main electrical source disconnected, connect the thermostat
wiring from the wiring connections on the thermostat to the terminal
board on the ignition module, as shown in Figures 18 or 19. Electronic
thermostats may require the common wire to be connected. Apply
strain relief to thermostat wires passing through cabinet. If air condition-
ing equipment is installed, use thermostat wiring to connect the Y and C
terminals on the furnace control board to the proper wires on the con-
densing unit (unit outside).
Set the heat anticipator in the room thermostat to 0.4 amps. Setting it
lower will cause short cycles. Setting it higher will cause the room
temperature to exceed the set points.
Some electronic thermostats do not have adjustable heat anticipa-
tors. They should be set to six cycles per hour. Follow the thermostat
manufacturer's instructions.
The 24-volt, 40 VA transformer is sized for the furnace components
only, and should not be connected to power auxiliary devices such as
humidifiers, air cleaners, etc. The transformer may provide power for an
air conditioning unit contactor.
Hi Fire Air Temp Rise
Lo Fire Air Temp Rise
°F
°C
°F
35 - 65
19.5 - 36
35 - 65
45 - 75
25 - 41.6
20 - 50
45 - 75
25 - 41.6
25 - 55
35 - 65
19.5 - 36
35 - 65
45 - 75
25 - 41.6
20 - 50
45 - 75
25 - 41.6
35 - 65
Min. Wire Size
Operating Weight
(awg) @ 75ft.one way
lbs.
14
122
14
126
14
136
14
142
12
145
12
156
Johnson Controls Unitary Products
°C
19.5 - 36
11.1 - 27.8
13.9 - 30.5
19.5 - 36
11.1 - 27.8
19.5 - 36
kg.
55.3
57.1
61.7
64.4
65.7
70.7