Operating Modes - Peavey Dual DeltaFex Owner's Manual

Peavey dual deltafex digital effects processor
Hide thumbs Also See for Dual DeltaFex:
Table of Contents

Advertisement

Available languages

Available languages

Operating Modes

Preset Recall Mode:
This is the default power-up mode. The Preset mode LED will be lit, the display will show the preset
number and the data wheel will scroll through presets. Setting the mode Select button to "Preset" will
put the unit into this mode at any time.
User Presets 00. - 99. will be shown first (with the decimal point lit), while fixed Factory Presets 00 - 99
will be shown next (without the decimal point lit).
A preset consists of: the settings for both effect engines (effect type, mix, parameters 1 & 2, level) and
the configuration (routing).
Store Mode:
Press the Store button to activate Store mode. The destination number will blink. If you are on a User
preset, the destination will initially be the same as the preset. If you are on a Factory preset, the default
destination will be the same preset number, but in the User bank. At this point, you have three options:
Edit Mode:
Press the Select button to enter Edit A or Edit B mode. (Shortcut: pressing the EDIT button when in
Preset mode will also enter Edit A mode.) One of the four LEDs to the right of the display will light.
Once in Edit mode, the EDIT button will scroll down through five parameters (if the effect is not off ): the
four shown next to each LED, and all LEDs on, indicating output level for effect A or B. At each stop the
display will show the value, and the data wheel can be used to edit it.
The parameter being edited/displayed belongs to either effect block A or B, indicated by the Mode
LEDs.
The CONFIG button will step through the four configurations (see page 9), which control how the two
effect engines are routed between the inputs and outputs for the current preset. Typically, you would
set this before editing the parameters, since it can (and most likely will) affect the overall sound – mix
ratios, depths, etc.
Note: The unit can be re-initialized to factory default settings by holding STORE and MODE
while powering up. This will copy the Factory presets to the User presets, and initialize any
globals (like bypass vs. mute) to their default setting. You will see "in" on the display for a few
seconds while the unit restores its default setting.
1. Press the Store button again to store into the current destination
2. Use the data wheel to choose a different location and then store
3. Press any other button to escape Store
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents