1. Intended Use
The charger is intended to charge and discharge NiCd or
NiMH chemistry rechargeable batteries only. It provides four
independent charging slots for AA or AAA rechargeable
batteries. The charger can also test and optimize the
maximum capacity of the rechargeable batteries. Each
charging slot has its own display to show various information
such as, charging current, battery voltage, charged capacity,
discharged capacity, battery internal resistance and time.
Second generation hardware including 16 bit Delta-Sigma
ADC provides improved charging circuit performance and
thermal management.
The charger can charge or test batteries of different type,
different size, and different capacity at the same time. Each
charging slot may be programmed with a different working
mode and current parameters if desired. When charging is
complete FULL will show in that channel display then the
maintenance charge is started automatically.
This product fulfills European and national requirements
related to electromagnetic compatibility (EMC). CE conformity
has been verified and the relevant statements are available
upon request.
Unauthorized conversion or modification of the charger is
prohibited and voids the manufacturer's warranty. Any usage
other than described above is not permitted and can damage
the product and lead to associated risks such as short-circuit,
fire, electric shock, etc. Please read the operating instructions
thoroughly and keep them for future reference.
2. Safety Instructions
The manufacturer assumes no liability for damages to
property or personal injury if the product has been abused,
modified or damaged by improper use or failure to observe
these operating instructions.
2.1 Product Safety
The product must not be exposed to substantial
mechanical strain or strong vibrations.
Do not operate the charger if it appears damaged in any
way.
The product must be protected against strong
electromagnetic
fields,
extreme temperatures, direct sunlight and moisture.
The manufacturer's instructions for the respective
batteries must be observed. Ensure the batteries can
accept the programmed charge and discharge rates
before attempting charging.
The product should not be connected immediately after it
has been brought from an area of cold temperature to an
area of warm temperature. Condensed water might
cause damage. Wait until the product adapts to the new
ambient temperature before use.
static
electrical
fields,
The product is to be used only in an indoor dry
environment.
Sufficient ventilation must be provided when operating
the charger. Never cover the ventilating slots of the
charger. Ensure adequate ventilation for the batteries
under charge. Do not place the unit on the carpet as this
can block ventilation slots on the charger body. Operate
only in a well ventilated area.
2.2 Battery Safety
Correct polarity must be observed while inserting the
batteries. Always insert the battery cells with the positive
tip facing the top of the charger.
Non-rechargeable batteries, rechargeable alkaline
batteries (RAM), alkaline batteries, lead acid batteries
and lithium batteries must not be charged with this
product. There is danger of fire or explosion!
Batteries should be removed from the device if it is not
used for a long period of time to avoid damage through
leaking. Leaking or damaged batteries might cause
chemical burns when in contact with skin; therefore use
suitable protective gloves to handle corrupted batteries.
Batteries must be kept out of reach of children and pets.
Batteries must not be dismantled, short circuited or
thrown into fire. Never allow battery contacts to become
shorted.
Use only NiMH or NiCd rechargeable batteries. Never
recharge non-rechargeable batteries due to risk of fire or
explosion of the batteries.
.
3. Delivery Contents
Battery Charger BT-C2400
Wall Power Adapter
Operation Instructions
4. Operating Elements
1. Power Jack
2. Battery Slots
3. Backlit LCD display
4. Buttons
1. Power Jack
1pc
1pc
1pc

Advertisement

loading

Summary of Contents for Opus BT-C2400

  • Page 1 OPERATING INSTRUCTIONS environment.  Sufficient ventilation must be provided when operating BT-C2400 V2.2 Battery Charger the charger. Never cover the ventilating slots of the charger. Ensure adequate ventilation for the batteries 1. Intended Use under charge. Do not place the unit on the carpet as this The charger is intended to charge and discharge NiCd or can block ventilation slots on the charger body.
  • Page 2 Only approved power supplies may be used to up to its maximum capacity at the selected current. Charge power the BT-C2400 charger. The included power supply termination or full charge is determined with a modified -dV provides +12Vdc at 1.0A. It has a coaxial DC power plug, (minus delta voltage) algorithm.
  • Page 3 CHARGE - TEST Mode: However actual discharge current may be lower depending on The CHARGE-TEST mode tests the present capacity of a battery internal resistance. rechargeable battery. The maximum capacity is determined by first fully charging the battery, then discharging the 6.3 DISPLAY Selection battery while measuring discharge current and time.
  • Page 4 200 ~ 1400 mA Discharge Current range 100 ~ 500 mA Max. Charging Capacity 20,000 mAh (20 Ah) 0 to 40 ℃ Operating Temperature One Year Limited Warranty Contact your retailer for warranty. Manufactured by: Opus Instruments Co. LTD support@dc-workshop.com...