Battery Charger BT-C2000
1. Intended Use
The charger is intended to charge and discharge NiCd or NiMH chemistry rechargeable batteries
only. It provides four independent charging slots for AA or AAA rechargeable batteries. The
included adapters provide the additional ability for C & D size rechargeable batteries. The charger
can also test and optimize the maximum capacity of the rechargeable batteries. Each charging slot
has its own display to show various information such as, charging current, battery voltage, charged
capacity, discharged capacity, battery internal resistance and time. Second generation hardware
including Delta-Sigma 16 bit ADC provides improved charging circuit performance and thermal
management.
The charger can charge or test batteries of different type, different size, and different capacity at
the same time. Each charging slot may be programmed with a different working mode and current
parameters if desired. When charging is complete FULL will show in that channel display then the
maintenance charge is started automatically.
This product fulfills European and national requirements related to electromagnetic compatibility
(EMC). CE conformity has been verified and the relevant statements are available upon request.
Unauthorized conversion or modification of the charger is prohibited and voids the manufacturer's
warranty. Any usage other than described above is not permitted and can damage the product and
lead to associated risks such as short-circuit, fire, electric shock, etc. Please read the operating
instructions thoroughly and keep them for future reference.
2. Safety Instructions
The manufacturer assumes no liability for damages to property or personal injury if the product
has been abused, modified or damaged by improper use or failure to observe these operating
instructions.
2.1 Product Safety
§ The product must not be exposed to substantial mechanical strain or strong vibrations.
§ Do not operate the charger if it appears damaged in any way.
§ The product must be protected against strong electromagnetic fields, static electrical fields,
extreme temperatures, direct sunlight and moisture.
§ The manufacturer's instructions for the respective batteries must be observed. Ensure the
batteries can accept the programmed charge and discharge rates before attempting
charging.
§ The product should not be connected immediately after it has been brought from an area
of cold temperature to an area of warm temperature. Condensed water might cause
damage. Wait until the product adapts to the new ambient temperature before use.
§ The product is to be used only in an indoor dry environment.
§ Sufficient ventilation must be provided when operating the charger. Never cover the
ventilating slots of the charger. Ensure adequate ventilation for the batteries under charge.
Do not place the unit on the carpet as this can block ventilation slots on the charger
body. Operate only in a well-ventilated area.
Page 1 of 6
- OPERATING INSTRUCTIONS
Battery Charger BT-C2000

Advertisement

loading

Summary of Contents for Opus BT-C2000

  • Page 1 Battery Charger BT-C2000 - OPERATING INSTRUCTIONS 1. Intended Use The charger is intended to charge and discharge NiCd or NiMH chemistry rechargeable batteries only. It provides four independent charging slots for AA or AAA rechargeable batteries. The included adapters provide the additional ability for C & D size rechargeable batteries. The charger can also test and optimize the maximum capacity of the rechargeable batteries.
  • Page 2: Power Supply

    The wall power adapter included is the main power supply for this charger. Only approved power supplies may be used to power the BT-C2000 charger. The included power supply provides +12Vdc at 1.0A It has a coaxial DC power plug, which inserts into the power jack on the rear of the charger main unit, of 5mm OD, 2.1mm ID with center positive.
  • Page 3: Mode Selection

    Example: Insert battery into a slot. CHARGE will flash in that channel display. Press CURRENT button to select 200, 400, 600, 800, 1000, (1200 or 1400) mA for the charge rate. If CURRENT button is not pressed the current will automatically default to 400 mA. Page 3 of 6 Battery Charger BT-C2000...
  • Page 4: Discharge/Discharge Refresh Modes

    A reading of 55 represents 55 milliohms or 0.055 ohms. NOTE: Due to greater contact resistance, measuring internal resistance of high capacity C and D cells with the included C&D to AA adapters is unreliable. Typically internal resistance of high Page 4 of 6 Battery Charger BT-C2000...
  • Page 5: Temperature Monitoring

    The charging/discharging process will only resume once the temperature of the batteries drops below 40 degrees Celsius (104 degrees F) or charger controller board temperature drops below 50 degrees Celsius (122 degrees F) as appropriate. Page 5 of 6 Battery Charger BT-C2000...
  • Page 6: Data

    Operating Temperature 0 to 40° C [Poor quality picture omitted (of C&D adapters installed)] One Year Limited Warranty Support in North America - Email: support@datalucis.com Manufactured by: Opus Instruments Co. Ltd, Shenzhen Guangdong, China Page 6 of 6 Battery Charger BT-C2000...