Westinghouse WRC613S Installation And User Manual page 7

Table of Contents

Advertisement

INSTALLATION
1. Using a spirit level mark a vertical centre line on the wall where the hood is to be positioned, and a horizontal line
at the hood base position. (See Figure 4 for relevant model)
NOTE. The height of the underside of the hood body must be a minimum of 600mm* to a maximum height of 800mm.
* If the instructions of the hob specify a greater distance than the minimum above, then that shall be the minimum
height for installation.
2. Mark the location for the flue cover wall mounting brackets and rangehood mounting points and anti-tilt fixing
points above the hood base using the hood base as a reference point
Min. 600 mm*
Max. 800 mm
Top of hob
WRC613S
A
600 mm
B
440 mm
250 mm
130 mm
230mm
250 mm
51 mm
B
A
WRC913S
900 mm
550 mm
ceiling
Flue cover wall
mounting brackets
Range hood
mounting points
Anti tilt fixing point
Fig. 6
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wrc913s

Table of Contents