Page 1
ORDER NO.PHAMOS0601005A1 Microwave Oven NN-SD986S / NN-H965WFB APH(USA) Please file and use this specified manual together with the service manual for Model NN-T695 (ORDER NO. PHAMOS0501001C1). SPECIFICATIONS...
Page 2
2006 Panasonic Home Appliances Microwave Oven (Shanghai) Co., Ltd. / All rights reserved. Unauthorized copying and distribution is a violation of law.
1. SCHEMATIC DIAGRAM 2. MEASUREMENTS AND ADJUSTMENTS...
Page 7
2.1. Adjustment of primary latch switch, secondary latch switch and short switch. 1. Mount the Primary latch switch, the Secondary latch switch and the short switch to the door hook assembly as shown in ILL. NOTE: No specific individual adjustments during installation of the Primary latch switch, Secondary latch switch or Short switch to the door hook are required.
2.2. Measurement of microwave output The output power of the magnetron can be determined by performing IEC standard test procedures. However,due to the complexity of IEC test procedures, it is recommended to test the magnetron using the simple method outlined below. Necessary Equipment: *1 liter beaker *Glass thermometer / *Wrist watch or stopwatch NOTE:...
RATED OUTPUT TEMPERATURE RISE 1200W Min. 18.5°F(10.3°C) 1300W Min. 19.8°F(11.1°C) 3. PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE NOTE: The U.S. Government standard is 5 mW/cm while in the customer’s home. 2mW/cm stated here is our own voluntary standard. (1mW/cm for Canada) 3.1.
supplied with the probe. 4. Tap the start pad or set the timer and with the magnetron oscillating, measure the leakage by holding the probe perpendicular to the surface being measured. 3.2.1. Measurement with the outer panel removed. Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted.
TROUBLESHOOTING Purpose: Simple way (3/23 seconds rule) of identifying whether it’s Magnetron, Inverter, or others. Set-up: The unit under question is connected through the Ammeter as shown below. Procedure: Follow the matrix table below to identify the problem source. Note: Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this procedure.
Page 18
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F3018-1200 DOOR KEY A F301A8D10SAP DOOR A (U) SD986S APH F30016G40HAP DOOR A H965WFB APH F302K4U00AP DOOR E (U) F30215G10XN DOOR KEY SPRING F30854U00AP DOOR C F31454U00AP DOOR SCREEN A F31467B00HAP DOOR SCREEN B H965WFB APH F02459660AP...
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F030A7B70AP LEAD WIRE HARNESS F030E6G30AP H.V.LEAD WIRE F03537B70AP LEAD WIRE HARNESS(U) (INCLUDING THERMISTOR) 7. DIGITAL PROGRAMMER CIRCUIT 7.1. NN-SD986S APH...