• Test 6 – Heater 1 and outlet thermistor Test (Gas
System off on gas models)
• The display will initially show "t6".
• Once the Start button is pressed, heater 1 turns on.
The display shall show the value of the outlet thermistor
from 00 to 137, which is considered a valid range. If the
value from thermistor is outside of the range, there is an
error in the outlet thermistor and control should display
"tE". If the display shows a value and doesn't change the
value, there is a heater 1 error.
g
GE imagination at work
T6 Test
GE Profile HE Dryer (9/16/08)