GE Profile DPGT650E Manual page 31

Profile he dryer
Table of Contents

Advertisement

• Test 5 – Humidity Sensor Test
• The display will initially show "t5".
• Once the Start button is pressed, the display will show a
value from 30 (very damp) to 255 (very dry) depending
on that state of the clothing that is being touched to the
sensor rods.
• The heater and drum motor shall be disabled while in
this test. This test must be able to run with the door
open or closed. The display will automatically update as
the state of the clothes changes.
• If display shows greater than 255, the sensor circuit is
defective.