Removal of Streamer Unit
Step
4. Remove the streamer unit
PCB.
1
Remove the screw of
the electrode plate with
a precise screwdriver.
2
Unfasten the 2 hooks
and remove the
streamer unit PCB.
3
Disconnect the
connector and remove
the limit switch.
48
Procedure
Limit switch Streamer unit PCB
Screw
Points
Electrode plate
(R13978)
(R5785)
(R5786)
Removal Procedure
Si04-756