Removal of Dehumidifying Solenoid Valve Coils
8. Removal of Dehumidifying Solenoid Valve Coils
Procedure
Step
Disconnect the
1
connector for the
dehumidifying solenoid
valve coils [S43].
Pull out the
2
dehumidifying solenoid
valve coils to remove.
30
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Dehumidifying solenoid valve coil
Dehumidifying solenoid valve coil
Points
Preparation
Remove the front grille
according to "Removal of
Front Grille".
(R5717)
[S43]
(R14155)
The dehumidifying solenoid
valve coils do not need
screws.
(R5719)
Removal Procedure
Si04-756