DRAINING THE RESERVOIR

CAUTION: YOU MUST DRAIN THE RESERVOIR AFTER EACH DAYS USE AND
BEFORE YOU PUT YOUR COMPRESSOR INTO STORAGE.
1. Turn the compressor off and
disconnect from the power
supply.
2. Put a container below the drain
valve to collect the condensate.
3. Open the drain valve slowly.
• Condensation will drain from
the reservoir.
4. Close the drain valve when the
reservoir has fully drained.

USING THE RESET BUTTON

This compressor has a thermal
overload device.
If the motor gets too hot, the thermal
overload device cuts the power
which prevents damage to the motor.
If the thermal overload device
operates, let the motor cool down for
5 minutes and push the reset button.
If you start the compressor and the
overload cutout operates again, stop
the compressor and disconnect from the power supply and have your
compressor examined by a qualified service agent.