Load monitoring

Advertisement

1/N/PE 50 Hz 230 V
L
N
PE
3RF21..-1..0.
F1
3RF23..-1..0. 3RF29..-0F.08
K1
1
L
A1 +
PE
A2 -
2
T
R1
R2
R3
Technische Änderungen vorbehalten. Zum späteren Gebrauch aufbewahren.
Subject to change without prior notice. Store for use at a later date.
© Siemens AG 2003
DC 24 V
L +
L -
A1 +
I<
A2 -
IN
OUT
I
≤50 mA = o. k.
OUT
I
>50 mA =
OUT
INPUT =
ON =
R4
R5
R6
25,5 (1)
21,5 (0.85)
A1
D out
D in
25,5 (1)
38 (1.5)
∅ 3,5 mm / PZ1
AWG
22,5 (0.89)
12 (0.47)
∅ 7 (0.27)
28,5 (1.12)
3RF29..-0F.08
0,5 ... 0,6 Nm
4.5 to 5.3 lb· in
7
1 x 0,5 ... 2,5 mm²
2 x 0,5 ... 1 mm²
7
1 x 0,5 ... 2,5 mm²
2 x 0,5 ... 1 mm²
1 x 20 to 12
Bestell-Nr. / Order No.: 3ZX1012-0RF00-2AW1