Cisco Linksys SFE2000 Administration Manual page 32

Fast ethernet switch release 1.0
Hide thumbs Also See for Linksys SFE2000:
Table of Contents

Advertisement

stacking connections. Concurrently, the Backup Master notifies the system administrator of
the failure by sending SYSLOG messages and SNMP traps.
Because all traffic has been routed around the failed unit, when it is disconnected from the
stack, the stack continues to run as long as all other stacking connections are left intact.
When a new unit is inserted in the stack and powered on, the following occurs:
1. The incoming unit, which is in stack mode, performs the Master Discovery process, and
may participate in the Master Election process.
If the incoming unit has a Unit ID of 1 or 2 (it is a master-enabled unit) it initiates the
Master Election process. However, because the running stack Backup Master has a
longer runtime (if it has been running for more than 10 minutes) it remains the Stack
Master and the incoming unit does not become the new Stack Master. This can cause
an incoming unit with a Unit ID of 1 to serve as the stack Backup Master, while the
current unit with the Unit ID of 2 remains the active Stack Master.
2. The Stack Master performs Unit ID allocation and the conflict resolution process.
If the incoming unit did not have an assigned Unit ID (that is, it is in factory default
mode), it is assigned the lowest available Unit ID by the Stack Master. We
recommend that you use the automatically-assigned unit ID mode because it
provides better resiliency to the stack.
If the incoming unit already has an assigned Unit ID, and that Unit ID is unused in
the current stack, the incoming unit keeps its assigned Unit ID and the Stack Master
applies any configuration relevant to that Unit ID to the incoming unit.
If the incoming unit already has an assigned Unit ID, and that Unit ID conflicts with a
unit ID in the current stack, the Stack Master allocates a new Unit ID to the incoming
unit, giving it the lowest available Unit ID. However, if the incoming unit has a
manually assigned Unit ID, the Stack Master cannot change it. If the incoming unit
cannot be assigned an available Unit ID, then it is shut down and is not joined to the
stack.
3. The Stack Master performs unit and port configuration for the incoming unit.
Any configuration information that is relevant to the number assigned to the
incoming unit is applied by the Stack Master. For example, if the incoming unit is
26
Linksys One Ready Communications Solution
Chapter 3: Connecting the Switch
Stack Troubleshooting and Maintenance
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sfe2000pLinksys sfe2000p

Table of Contents