Page of 2
Download Bookmark Comment

Channel Master 1008IFD Specifications

Channel master 1008ifd signal meters: specifications.
Hide thumbs
   
BATTERY CHARGING
User Instructions
For optimum battery life, follow these guidelines:
CAUTION:
Model 1008IFD Dual Satellite Signal Meter
The 1008IFD is factory shipped with the battery in a
with rechargeable battery and charger
partially charged state. It should be used without charging until
the "BATTERY TEST" mode reaches the yellow position. It should
INTRODUCTION
then be charged overnight using the charger provided. The unit
should then be charged overnight after each three(3) hours of use.
The 1008IFD satellite signal meter has been designed for the installation and mainte-
nance of a satellite TV system. Its primary application is in dual satellite, single dish
Note: Optimum battery performance is obtained after the first few charge/discharge
installations. It features signal strength measurement by both meter indication and audi-
cycles. The powering switch must be in the "BATTERY OFF" position during charging.
ble tone indication for dish antenna peaking. LNB voltage and current measurement is
also provided. An internal, rechargeable nicad battery pack with output switchable
between 13V, 18V, 13V/22 KHz and 18V/22 KHz allows a dish antenna to be installed
prior to installation of the satellite receiver. The output voltage and 22 KHz tone pres-
ence from a satellite receiver may also be monitored. The internal 22 KHz generator
SATELLITE ACCESSORY LIMITED NINETY (90) DAY WARRANTY
allows "alternate satellite" selection on certain types of systems with an integrated
This Channel Master
®
equipment is warranted to be free from defects in material and
LNB/multiswitch.A 117 VAC wall plug type charger is included.
workmanship under normal use and service. Channel Master shall repair or replace
TECHNICAL SPECIFICATIONS
defective equipment, at no charge, or at its option, refund the purchase price, if the
equipment is returned to Channel Master not more than ninety (90) days after ship-
EACH METER SECTION
ment. Removal or replacement of equipment and its transportation shall not be at
Frequency range
950-2150MHz
the cost of Channel Master except Channel Master shall return repaired or replaced
equipment freight prepaid.
Impedance
75 ohm
-32 to + 4 dBm 1 transponder
This Warranty shall not apply to equipment which has been repaired or altered in
Sensitivity (per transponder)
any way so as to affect its stability or durability, nor which has been subject to mis-
-41 to - 5 dBm 8 transponders
use, negligence or accident. This warranty does not cover equipment which has
-44 to - 8 dBm 16 transponders (eg DBS 1, 2, 3)
been impaired by severe weather conditions such as excessive wind, ice, storms,
Insertion Loss
4 dB
lightning or other natural occurrences over which Channel Master has no control,
nor shall this Warranty apply to equipment which has been operated or installed
Voltage Drop
0.1V (Sat receiver to LNB)
other than in accordance with the instructions furnished by Channel Master.
Indication
Analog Panel Meter 100uA FSD
Claimants under this Warranty shall present their claim along with the defective
Acoustic Indicator
0.2 to 5.0 KHz
equipment to Channel Master immediately upon failure. Non-compliance with any
LNB Voltage Measurement
0-25VDC
part of this claim procedure may invalidate this Warranty in whole or in part.
LNB Current Measurement
0-500mA
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER AGREEMENTS AND
Battery Powered Output Power
13V, 18V, 13V/22 KHz, 18V/22 KHz
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
Tone Output
0.6V square wave, 22 KHz
PURPOSE, CHANNEL MASTER DOES NOT AUTHORIZE ANY PERSON TO ASSUME
Tone Indicator
Requires >300mV, 20-24KHz
FOR IT THE OBLIGATIONS CONTAINED IN THIS WARRANTY AND CHANNEL
Battery Life between charges
3 hours continuous at 170mA LNB current
MASTER NEITHER ASSUMES NOR AUTHORIZES ANY REPRESENTATIVE OR
OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH
Charge Interval - typical
2 weeks in single satellite installations
THE EQUIPMENT DELIVERED OR PROVIDED.
Charge Interval - typical
1 week in dual satellite installations
IN NO EVENT SHALL CHANNEL MASTER BE LIABLE FOR ANY LOSS OF PROFITS,
Wall Plug Charger Output
24VDC at 100 mA conn. center positive
LOSS OF USE, INTERRUPTION OF BUSINESS, OR INDIRECT, SPECIAL OR CONSE-
Charge power/time
24VDC at 60 mA for 14 hours
QUENTIAL DAMAGES OF ANY KIND.
RF Connectors
Type F female
In no event shall Channel Master be liable for damages in an amount greater than
Dimensions H x W x D
5.3" x 7.04" x 3.81" (135 x 179 x 97 mm)
the purchase price of the equipment.
Weight
2.8 lb. (1276g)
Channel Master
®
LLC reserves the right to modify their designs or specifications, in the light of future
developments, without prior notice. The performance figures quoted are typical and are subject to
www.channelmaster.com
©2002 Channel Master LLC (8000860)
Printed in China
normal manufacturing and service tolerances.

   Related Manuals for Channel Master 1008IFD

   Summary of Contents for Channel Master 1008IFD

  • Page 1

    IN NO EVENT SHALL CHANNEL MASTER BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF USE, INTERRUPTION OF BUSINESS, OR INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES OF ANY KIND. In no event shall Channel Master be liable for damages in an amount greater than the purchase price of the equipment. www.channelmaster.com ©2002 Channel Master LLC (8000860)

  • Page 2

    SAT Rx LNB Satellite Signal Level Meter Model 1008IFD 1) Use 1008IFD battery power (not Sat Rx power) as the Sat Rx may not be able to power 2 LNBs simultaneously. The tone feature is best switched off in this application.

Comments to this Manuals

Symbols: 0
Latest comments: