Install The Door Control - Chamberlain Whisper Drive Security+ 459950 Owner's Manual

Chamberlain whisper drive 459950 garage door openers: user guide
Hide thumbs Also See for Whisper Drive Security+ 459950:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION STEP 6

Install the Door control

Locate door control within sight of door, at a minimum
height of 5 feet (1.5 m) where small children cannot
reach, away from moving parts of door and door
hardware. If installing into drywall, drill 5/32" holes and
use the anchors provided. For pre-wired installations
(as in new home construction), it may be mounted to a
single gang box (Figure 2).
NOTE: The functional temperature range of the door
control is between -4° F (-20° C) and 122° F (50° C).
Scroll speed of display is slower at lower temperatures
although the door control remains fully functional.
CAUTION: Continuous exposure of the door control to
temperatures below -22° F (-30° C) may damage the
LCD screen.
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back of
door control by color: white wire to W (2) and white/red
wire to the R (1).
2. Remove cover by gently prying at slot in top of the
cover with a small flat head screwdriver. Fasten with
6ABx1-1/4" self-tapping screws (drywall installation) or
6-32x1" machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to protrude
above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid cracking
plastic housing. Do not overtighten.
• Insert top tabs and snap on cover.
3. (For standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated staples
to secure wire in several places. Do not pierce wire
with a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety reverse test label in a prominent
location on inside of garage door.
NOTE: DO NOT connect power and operate opener at
this time. The trolley will travel to the full open position
but will not return to the close position until the sensor
beam is connected and properly aligned.
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Disconnect ALL electric and battery power BEFORE
performing ANY service or maintenance.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet (1.5 m), and away
from all moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white;
white/red to red.
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1-1/4"
Control Panel (std installation)
Screw 6-32x1"
Control Panel (pre-wired)
Figure 1
REMOVE & REPLACE COVER
Push Bar Cover
Bell
Wire
R
W
2
1
(BACK VIEW)
Control Console Connections
Strip wire 7/16" (11 mm)
7/16" (11 mm)
Red
17
Insulated
Staples
Drywall Anchors
Figure 2
PRE-WIRED INSTALLATION
Top
Mounting
Hole
Terminal
Screws
Bottom
Mounting
Hole
To insert or release wire,
push in tab with screwdriver tip
White
Grey
24 Volt Bell Wire

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents