Download Print this page

Chamberlain 916GA User Manual page 3

The protector system safety sensors

Advertisement

ASSEMBLE SAFETY SENSORS
Insert hex head bolt through safety sensor and slide safety sensor into
bracket. Secure with wing nut.
MOUNT SAFETY SENSORS
Mount safety sensor assembly to post using appropriate hardware.
Safety sensors must be installed no higher than 24" (61 cm) above
the ground.
NOTE: Install safety sensor assembly with the two holes in the bracket
facing up and the LEDs are visible at the top.
Mark Safety
Sensor Post No
Higher than 24"
(61 cm)
WIRE SAFETY SENSORS
1. Separate wires.
2. Strip 7/16" (11 mm) of insulation from low voltage wires. UL approved Class 1 or Class 3 direct burial/underground, sunlight/UV resistant 16 gauge
2-conductor/standard low voltage landscape lighting wire.
The following products, available at most home center/hardware stores, meet these specifications:
• Chamberlain models 917GA pr 918GA
3.
Combine all like-colored wires and twist together with wire nuts.
Wire Nuts
Safety Sensor Wires
Low Voltage
Wires to
Control Box
Conduit
Safety Sensor Post
Safety Sensor Post
3
Safety Sensor
Assembly
Safety Sensor Post