IF WATER RUNS OUT AT OVERFLOW DRAIN:
1.
Make sure urn is level and overflow tube is vertical.
2.
Remove fuse from rear of side box.
3. If water continues to flow, solenoid valve is dirty or not seating properly. Replace solenoid as described above.
NO WATER FROM SPRAY HEAD:
1.
Check fuse first.
2a. For all urns except CL's: Depress BREW switch and release. If switch remains lit, water pump is probably not operating.
Lift off side box door and check if fan on water pump is rotating. If not, replace pump as described below.
2b.
For CL urns: Turn brew timer knob clockwise. Replace timer if it does not go on. If timer goes on but pump doesn't,
replace pump.
REPLACING WATER PUMP:
1. Shut off water supply and remove fuse. Drain urn to level of water faucet.
2. Lift off side box door and disconnect the two pump wires.
3. Loosen union fittings on pump and remove pump from urn (Refer to page 15, Installation & Removal of Water Pump.)
4. Replace pump and follow priming instructions on page 2.
CHECKING SOLID-STATE TIMER (ALL URNS EXCEPT CL's): Press and hold BREW switch for 10 seconds. Brew cycle
should start. If water stops coming from spray head as soon as BREW switch is released, timer is not operating. Replace it.
(Instructions below.) If no water comes from spray head when BREW switch is pressed, replace switch.
NOTE: To check mechanical timer on CL urns, refer to NO WATER FROM SPRAY HEAD.
REPLACING SOLID-STATE TIMER:
1.
Remove fuse, lift off side box door, and remove timer from bracket.
2.
Carefully note locations of colored wires on timer board, then remove wires.
3.
Replace timer and reassemble unit in reverse order.
BLENDING - AUTOMATIC TYPE (ALL FE):
OPERATION:
The agitator pump circuit is programmed to operate immediately after brewing cycle. The circuit pumps air through the coffee
gauge glass(es) into the coffee liner(s). The complete cycle takes about 20 seconds. For additional blending, simply press the
BLEND switch.

MAINTENANCE:

If agitation is not sufficient to blend coffee, check flexible tubing , and glasses and fittings, for possible air leaks. Replace as
necessary.
If agitator pump does not operate immediately after brewing cycle or when BLEND switch is pressed, replace agitator pump or
solid state agitator timer.
If agitator pump comes on immediately after brewing cycle, but does not operate when BLEND switch is pressed, replace
BLEND switch.
BLENDING - MANUAL TYPE (CL URNS):
OPERATION:
Immediately after brewing cycle, depress BLEND switch and hold for about 20 seconds. Your coffee will be completely blended
and ready to serve.
MAINTENANCE:
If agitator pump does not operate when BLEND switch is pressed, replace switch, if pump still does not operate, replace pump.