1. TECHNICAL DATA

Model
Compression and tensile force
Strokes
Power supply voltage
Current absorbed at nominal load
Power absorbed at nominal load
No-load traverse speed
No-load stroke time (215 mm)
Service type
Operating temperature
Degree of protection for electrical devices
Synchronized operation
Static seal strength
Opening stroke-end
Closing stroke-end
Power supply cable length
Chain outlet
Dimensions
Device weight
The technical data provided above is non-binding and subject to change, even without advance notice.
Selecting the cross-section of the power supply cables

2. RATING AND MARKING

The rating data is provided on an adhesive polyethylene label attached
to the exterior of the device. The values are compliant with that required
by the EC standards in force. An example of the label is shown in the
photo below.
Pagina 12
W
Cable cross section
4.00 mm²
2.50 mm²
1.50 mm²
0.75 mm²
0.50 mm²
C
I
LOUD
70, 125, 170, 210mm
Electronic, set by dip-switches
By power absorption
Max cable length
~ 270 m
~ 170 m
~ 100 m
~ 50 m
~ 35 m
WiCloud
200 N
24 V
0.32A
7.5W
8mm/s
27 s
S
of 3 min
2
- 5 + 65 ºC
IP32
NOT provided for
1000N
2m
Central
28x28x310mm
0.660kg