IF
EQU
NE
GT
LT
GOTO
10.7 Checking and Changing
Q Parameters
During a program run or test run, you can check or change Q
parameters if necessary.
If you are in a program run, interrupt it (for example by pressing
the machine STOP button and the INTERNAL STOP soft key). If
you are doing a test run, interrupt it.
To call the Q parameter functions, press the Q key.
Enter the Q parameter number and press the ENT key.
The TNC displays the current value of the Q parameter
in the dialog line.
If you wish to change the value, enter a new value,
confirm it with the ENT key and conclude your entry
with the END key.
To leave the value unchanged, terminate the dialog
with the END key.
260
www.EngineeringBooksPdf.com
If
Equals
Not equal
Greater than
Less than
Go to