Figure 20; Table 14 - Nortel QPC757 Installation Manual

Isdn primary rate interface
Table of Contents

Advertisement

Page 56 of 188
PRI installation: XT, 71
553-2901-200
Standard 11.00
Procedure 8
Installing the QPC720 PRI in an XT, 71
1
Determine the cabinet and shelf location of the circuit card to be
installed. The following slots can be used if they are not required for
other cards.

Table 14

Shelf and slot location of QPC720 in XN, XT, and option 71
System
XN/XT
71
Note 1: DTI/PRI packs require two slots. The slot indicated is the maximum slot
that the pack resides in. For example, in slot 14, the pack uses slots 13 and 14.
Note 2: A DTI/PRI pack cannot be installed in slot 11. The pack would come in
contact with the BTU installed between slots 11 and 12.
Note 3: A DTI/PRI pack could reside in slots 10 and 11, but cannot reside in slots
11 and 12 because of powering restrictions.
Note 4: The power regulator (NT6D81AA) can be substituted by the DTI/PRI
packs, provided the balance of equipment in card slots 1 through 8 are already
equipped.
2
Unpack and inspect circuit cards.
3
Set option switches on the PRI circuit card. See
Table
15.
August 1996
Shelf
QSD39 Network (LH)
QSD40 Network (RH)
QSD39 DTI/PRI only
QSD40 DTI/PRI only
NT7D44 Mass Storage
QCA 55/58 CAB
NT7D45 Mass Storage
QCA 23/24 CAB
NT8D35 CPU/NET
NT8D35 DTI Exp Cube
NT8D47 RPE Cube
Slot
5–10 Note 1
5–10 Notes 1, 2
2–10 Notes 1, 3
12–14
2–3 Note 1
5–13
2–8 Notes 1, 4
5–10 Notes 1, 4
5–10 Note 1
13–14
2–3 Note 1
5–14
1, 11, 12

Figure 20

and