Important Safety Information - Danby DAC150EB1GDB Owner's Use And Care Manual

Table of Contents

Advertisement

Available languages

Available languages

ELECTRICAL SPECIFICATIONS
1) All wiring must comply with local and national electrical
codes and must be installed by a qualified electrician.If
you have any questions regarding the following
instructions, contact a qualified electrician.
2) Check available power supply and resolve any wiring
problems BEFORE installing and operating this unit.
3) This 115V or 230/208V air conditioner uses 12 or less
nameplate amps and may be used in any properly wired,
general purpose household receptacle. See Table 1 for
specifications for individual branch circuit.
4) For your safety and protection, this unit is grounded
through the power cord plug when plugged into a
matching wall outlet. If you are not sure whether your
wall outlet is properly grounded, please consult a
qualified electrician.
5) The wall outlet must match the 3-prong plug on the
service cord supplied with the unit. DO NOT use plug
adapters. See Table 2 for receptacle and fuse
information. If it is necessary to use an extension cord to
connect your air conditioner, use an approved "air
conditioner" extension cord only (available at most
local hardware stores).
6) The rating plate on the unit contains electrical and other
technical data. The rating plate is located on the right
side of the unit, above the power cord.
ENERGY SAVING TIPS
Your Danby appliance is designed to be highly efficient in energy savings. Follow these recommendations for
greater efficiency.
1) Select a thermostat setting that suits your comfort needs and leave at that chosen setting.
2) The air filter is very efficient in removing airborne particles. Keep the air filter clean at all times. (Usually cleaned every
2 weeks depending on indoor air quality).
3) Use drapes, curtains or shades to keep direct sunlight from penetrating and heating the room, but do not allow drapes
or curtains to obstruct the air flow around the unit.
4) Start your air conditioner before the outdoor air becomes hot and uncomfortable, to avoid an initial period of
discomfort while the unit is cooling off the room. Use of the automatic start/stop programmable TIMER feature can be
a major asset in this regard if utilized to the fullest extent.
5) When outdoor temperatures are cool enough, use the FAN MODE only, on HIGH, MEDIUM, or LOW setting. This circulates
indoor air, providing come cooling comfort, and utilizes less electricity than when operating on a cooling setting.

IMPORTANT SAFETY INFORMATION

Suggested Individual Branch Circuit
Nameplate Amps
12 or less
AWG- American Wire Gauge
*Based on copper wire at 105°C temperature rating.
Recept
Model
DAC150EB1GDB
R
a
e t
d
V
o
s t l
A
m
s p
Wall Outlet
F
u
s
e
S
z i
e
i T
m
e
D
e
a l
y
F
u
(or Circuit Breaker)
2
TABLE 1
*AWG Wire Size
TABLE 2
and Fuse Types
DAC180EB1GDB
DAC250EB1GDB
1
2
5
2
4
0
1
5
1
5
1
5
1
5
s
e
P
Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.
1
4
2
5
0
3
0
2
0
u l
g
T
y
p
e

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dac180eb1gdbDac250eb1gdb

Table of Contents