CN101 Power
1 Ground (Yel/Grn)
3 120vac N (Yel)
5 120vac L (Blk)
CN301
1-Water Level Sensor (Brn)
2-Water Level Sensor (Red)
3-Water Level Sensor (Yel)
4-Water Level Sensor (Gry)
5-Overflow (S/Blu)
6-Flow Meter (Vio)
7 +5vdc (Pnk)
8-Leakage Sensor (Wht)
9-Thermistor (Blk)
10 +12vdc (Blu)
11-Door Sense (Blu)

Dry System

Assy Case Vent
Double Shaft Mtr
Assy Duct Condenser
Air Exhaust
Main PCB
CN102
1-6 (S/Blu-S/Blu) +5vdc
2-6 (S/Blu-S/Blu) +12vdc
CN302
1-Half Load Sense (Blk)
2-Turbidity Transmitter (Red)
3-Trubidity Receiver (Vio)
4-Ground(Org)
5 + 5vdc (Pnk)
6-Rinse Sense (Yel)
Main PCB is located
behind bottom
access panel
Assy Dry Duct
Air Intake
T202-(CN101-3)
Heater (Red-Yel) (120vac)
CN501
3-1 +5vdc
CN202
1-(CN101-3) Valve (Brn-Yel) 120vac
5-(CN101-3) Pump (Org-Yel) 120vac
CN201
1-(CN101-3) Disp Wax Mtr (Wht-Yel) 120vac
3-(CN101-3) Half Load (Vio-Yel) 120vac
5-(CN101-3) Fan Mtr (S/Blu-Yel) 120vac
7-(CN101-3) Wash Mtr (Blu-Yel) 120vac
9-(CN101-3) Wash Mtr (Wht-Yel) 120vac
Single rear leg is
adjustable from
front. Retract to
remove D/W
Sump & Heater
T201 L1 (Blk)
(120vac)
Storm wash
Nozzle
3