Whirlpool LHB Series Product Introduction page 31

Table of Contents

Advertisement

Display
Functionality
Check
• Inlet Valve & Pressure
sensor check
• Motor & Slot sensor
Check
• Torque Motor
Diagnostic Routine
To Be Done /
Monitored
• Fill will be done with
valve for 15 litres
• LEDs will be turned on in
sequence while filling
• Motor Agitation CW/CCW
with Brake actuator ON
•LEDs will be turned on in
sequence
• Water in the system will
be drained
• Torque Motor will be
turned ON
• LEDs will be turned on in
sequence
• If Water is drained till
reset level in A04 Phase,
A05 will be skipped.
Failure
Indication
Low Water Level
LED glows with
Buzzer tone.
Check Water LED
glows with buzzer
tone.
Wash LED glows
along with buzzer
1. Motor, 2. Capacitor, 3. Brake
tone
Actuator, 4. Slot sensor & its
Connections & replace
accordingly
Child lock & Wash
LED glows along
with buzzer tone
Spin LED glows with
buzzer tone
Diagnosis
Check for Pressure sensor,
Its connection to PCB &
then Replace it.
Check for Inlet Valve & its
connection, Pressure hose
puncture & Kink & then
replace accordingly.
Check for
Motor wire cut(Red or
Yellow wire)
PCB Replacement
Check for Torque Motor, Its
connection & replace
accordingly.

Advertisement