Specifications; Cooling Performance - Friedrich VRP12K Service And Parts Manual

Hide thumbs Also See for VRP12K:
Table of Contents

Advertisement

Cooling Performance

Model
Cooling Performance Data (Cooling Standards: 95°F DB/75°F WB outdoor, 80°F DB/67°F WB indoor)
Voltage
Cooling Btu (Rated)
Cooling Btu (Min. – Max)
Outdoor Operating Range (°F)
Power (W)
SEER
EER
Sensible Heat Ratio
Cooling Amps
Heat Pump Performance Data
Heating Btu (Rated @ 47° F)
Heating Btu (@ 17° F)
Heating Btu (Min. – Max.)
Heat Pump Outdoor Operating
Range (°F)*
COP (Rated @ 47° F)
COP (@ 17° F)
HSPF
Heating Power (W)
Heating Amps
14

SPECIFICATIONS

VRP12K / VRP12R
230/208
265
12,000
4,000 – 16,000
55 – 115
923
20.0
13.0
0.71
4.3
11,500
7,100
4,000 – 14,000
0 – 70
3.4
2.2
10.0
991
4.8
4.1
Figure 201 (Cooling Performance)
VRP24K / VRP12R
230/208
265
23,400
12,000 – 28,000
55 – 115
2138
17.5
11.0
0.7
10.0
21,000
13,000
12,000 – 26,000
0 – 70
3.1
2.4
10.0
1954
9.1
7.8
VRP36K
230/208
33,400
20,000 ‑ 36,000
55 ‑ 115
2990
15.5
11.0
0.76
14.2
28,500
18,300
16,000 ‑ 30,000
0 ‑ 70
3.25
2.29
8.6
2570
12.26