WARNING
Risk of Fire or Electrical Shock
• Connect only to an outdoor receptacle protected by a Ground Fault Circuit Interrupter (GFCI).
• Connect directly to an outdoor receptacle with a "while in use" weatherproof cover.
• Mount to a vertical surface at least 2 feet above ground. Do not lay product on ground while in use.
• Do not exceed rated capacity of connected extension cord or timer.
• Do not immerse in water.
NOTICE
NOTICE
• No user serviceable parts inside.
Ratings
18/3 AWG SJTW cord
120 VAC 60 Hz, 8.3 A General Purpose
120 VAC 60 Hz, 8.3 A Resistive
1000 W Tungsten
Suitable for damp locations
Installation/Operation:
1.
Mount the device in a vertical position near a 3-conductor outlet with the receptacles facing
downward, at least 2 feet above the ground.
2.
Plug the timer's 3-prong plug into a GFCI Protected outlet.
3.
Connect directly to an outdoor receptacle with a "while in use" weatherproof cover.
4.
Rotate the timer dial to the OFF position and then insert the plug from light source into one of
the timer receptacles.
NOTE: Be sure to keep the timer away from the light source bulb so the timer can detect
natural light and darkness only.
5.
After the light is plugged in, rotate the timer dial to the desired program mode.
6.
If the lights have their own switch, move switch to the ON position.
TROUBLESHOOTING
Problem
Lights do not turn on at dusk
Lights do not turn ON when timer is in
ON position
Lights do not immediately turn on at dusk
or off at dawn
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES • CONSERVER CES INSTRUCTIONS
AVERTISSEMENT
• Raccorder exclusivement à une prise extérieure protégée par un disjoncteur différentiel (GFCI).
• Raccorder directement à une prise extérieure comportant un couvercle à l'épreuve des intempéries fermé
durant l'utilisation.
• Monter sur une surface verticale à au moins 60 cm au-dessus du sol. Ne pas coucher le produit au sol
durant l'utilisation.
• Ne pas dépasser la capacité nominale du cordon de rallonge ou de la minuterie.
• Ne pas immerger dans l'eau.
AVIS
AVIS
• Ne contient aucune pièce réparable par l'utilisateur.
Caractéristiques
Cordon SJTW de 18/3 AWG
120 V c.a., 60 Hz, 8,3 A usage général
120 V c.a., 60 Hz, 8,3 A résistif
1000 W tungstène
Convient aux endroits humides
Installation/fonctionnement :
1.
Monter l'appareil en position verticale près d'une prise de courant à 3 conducteur, avec les
prises de la minuterie tournées vers la bas à au moins 60 cm au-dessus du sol.
2.
Brancher la fiche 3 broches de la minuterie sur une prise protégée par un disjoncteur
différentiel (GFCI).
3.
Raccorder directement à une prise extérieure comportant un couvercle à l'épreuve des
intempéries fermé durant l'utilisation.
4.
Mettre le cadran de minuterie en position OFF puis brancher la fiche du luminaire sur l'une
des prises de la minuterie.
REMARQUE : Veiller à bien tenir la minuterie à l'écart du luminaire afin qu'elle puisse détecter
uniquement la lumière et l'obscurité naturelles.
5.
Une fois les luminaires branchés, tourner le cadran de la minuterie jusqu'au mode de
programme souhaité.
6.
Si les luminaires ont leur propre interrupteur, les mettre en position de marche.
Possible Cause
Too much ambient light in area to detect darkness
Timer is not receiving power or the lights are not in ON position
15-minute time delay to avoid flickering of lights due to sensing
temporary external lights (not sunrise)
Risque d'incendie ou de choc électrique
Warranty service is available by either (a) returning the product to the dealer from whom
the unit was purchased or (b) completing a warranty claim online at www.intermatic.
com. This warranty is made by: Intermatic Incorporated, 1950 Innovation Way, Suite 300,
Libertyville, IL 60048. For additional product or warranty information go to: http://www.
Intermatic.com or call 815-675-7000.
Timer Dial
Receptacle
Correction Action
Move lights away from timer or reposition timer so it does not face outside light.
Be sure timer is receiving power. The LED should light up when plugged into an outlet and put in
the ON position.
None. Lights will turn on/off after 15-minute delay.
Minuterie extérieure à prises
Ce service de garantie est disponible (a) en retournant le produit au vendeur auprès
duquel l'unité a été achetée ou (b) en remplissant un formulaire en ligne de réclamation
de garantie sur www.intermatic.com. Cette garantie est faite par : Intermatic Incorporated,
1950 Innovation Way, Suite 300, Libertyville, IL 60048. Pour les services de garantie,
accédez à la page suivante : http://www.Intermatic.com ou appelez au 815-675-7000
Cadran de
minuterie
Timer Dial
Prise
Receptacle
Au moins 60 cm au-dessus
du niveau du sol
Outdoor Plug-in Timer
MODEL: HB51K
ON
Receptacle
At least 4.6 feet
At least 2 feet
Above ground level
Above ground level
MODÈLE : HB51K
ON
Receptacle
Prise
At least 4.6 feet
Above ground level

Advertisement

loading

Summary of Contents for Intermatic HB51K

  • Page 1 WARNING Risk of Fire or Electrical Shock the unit was purchased or (b) completing a warranty claim online at www.intermatic. • Connect only to an outdoor receptacle protected by a Ground Fault Circuit Interrupter (GFCI). com. This warranty is made by: Intermatic Incorporated, 1950 Innovation Way, Suite 300, •...
  • Page 2 (b) el llenado de una reclamación de garantía • Conecte solo a un receptáculo para exteriores protegido con un interruptor de circuito de pérdida de conexión en línea en www.intermatic.com. Esta garantía la otorga: Intermatic Incorporated, 1950 a tierra (GFCI, por sus siglas en inglés).