CAUTIONS
WARNING: To reduce the risk of personal injury, do not bend the
blade brackets when installing the brackets, balancing the blades,
or cleaning the fan. Do not insert foreign objects in between rotating
fan blades.
WARNING: To reduce the risk of fire, electric shock, or personal
injury, mount to outlet box marked "Acceptable for Fan Support" and
use mounting hardware provided with the box.
WARNING: To reduce the risk of fire, electric shock, do not use this
fan with any solid-state speed control device.
This product must be mounted and wired in compliance with all local
and national electrical codes.
Before wiring the ceiling fan, turn off electric power at the circuit
breaker or fuse box and leave off until installation is complete.
Mount outlet box so that it will support at least 35 pounds.
Note: the weight of the fan is as follows:
PFC-48 14 lbs. PFC-56 20 lbs.
LOCATION
1. When fan is installed, you must allow a minimum of 10 feet be-
tween floor and bottom of fan blades.
2. For this model, the center of the fan must be located at least 32"
from any vertical surface - wall, doors, partitions, etc. This allows
minimum clearance for fan blades.
3. Do not mount fan below, next to or between air ducts, beams or
any other obstructions which may interfere with the natural air flow
pattern created by the fan.
4. Place fans near constantly opening doors and shipping bays to
produce an "air shield" effect that helps keep out cold air in winter
and dust, odors and insects in the summer.
5. If desired, fans can be installed directly above heat producing
machinery to reclaim the heated air.
6. For maximum air flow, fans should be located above aisles in
warehouses and storage areas.
7. Make sure fan voltage is compatible with your electrical system.
8. FOR SLOPED CEILING INSTALLATIONS ONLY: Ball and socket
mounting system will work on sloped ceilings up to 22° maximum
(rise/run = 5/12).
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Photo shows
hardware included
with your new
ceiling fan.
MOUNTING
BRACKET
DOWN ROD
BUSHING
SET SCREW
LOCK BOLT
LOWER
CANOPY
BLADE SUPPORT
MOTOR UNIT
GREEN
GREEN
WHITE
BLACK
OUTLET BOX
UPPER CANOPY
SPRING BUSHING
NUT
COTTER PIN
LOCK WASHER
BOLT
BLADE
BLADE
HOLDER
GASKET
FIGURE 1
BRACKET
SUPPLY
GROUND
SUPPLY NEUTRAL
SUPPLY HOT
FIGURE 2

Advertisement

loading

Summary of Contents for NuTone PFC-48II SERIES

  • Page 1 Industrial Paddle Fan MODELS: PFC-48II & PFC-56II /SERIES CAUTIONS WARNING: To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
  • Page 2: Important Safeguards

    Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599. Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9. WIRES...

This manual is also suitable for:

Pfc-56ii series