ADTRAN E220/220 Installation & Maintenance
ADTRAN E220/220 Installation & Maintenance

ADTRAN E220/220 Installation & Maintenance

T1 htu-c hdsl transceiver unit

Advertisement

Quick Links

PRACTICES
1.
GENERAL ................................................................... 1
2.
INSTALLATION ........................................................... 2
3.
CONNECTIONS .......................................................... 4
4.
HDSL SYSTEM TESTING .......................................... 5
5.
CONTROL PORT OPERATION ................................. 6
6.
HDSL DEPLOYMENT GUIDELINES ........................ 13
7.
TROUBLESHOOTING PROCEDURES ................... 13
8.
MAINTENANCE ........................................................ 14
9.
PRODUCT SPECIFICATIONS ................................. 14
Appendix A. HDSL LOOPBACKS .................................. A-1
FIGURES
Figure 1.
ADTRAN HTU-C .............................................. 1
Figure 2.
HTU-C Edge Connector Wiring ....................... 4
Figure 3.
HTU-C Span Powering Diagram ..................... 4
Figure 4.
HTU-C Bantam Jack Arrangement ................. 5
Figure 5.
HDSL Loopbacks ............................................. 5
Figure 6.
RS-232 (DB9) Pin Assignments ...................... 6
Figure 7.
Introductory Menu Screen ............................... 8
Figure 8.
HDSL Main Menu Screen ................................ 8
Figure 9.
Current System Status Screen ........................ 9
Figure 9A. Current System Status Screen - HRE ............. 9
Figure 10. Performance History Screen ......................... 10
Figure 10A. Performance History Screen - HRE .............. 10
Figure 11. Loopback Options Screen ............................. 11
Figure 12. Self Test Options Screen .............................. 11
Figure 13. Provisioning Screen ...................................... 12
Figure 14. Troubleshooting Display ................................ 12
Figure 15. HDSL Deployment Guidelines ...................... 13
TABLES
Table A.
Front Panel Rotary Switch Option Settings .... 2
Table B.
SW1 Option Settings ....................................... 3
Table C.
Front Panel Indicators ..................................... 3
Table D.
Screen Abbreviations ...................................... 6
Table E.
HDSL Loss Values ........................................ 13
Table F.
Loop Insertion Loss Data .............................. 13
Table G.
Troubleshooting Guide .................................. 14
Table H.
HDSL 220/E220 Low Voltage HTU-C
Specifications ................................................ 15
Table A-1. HDSL Enhanced Loopback Control
Codes .......................................................... A-1
Table A-2. Inband Addressable Loopback Codes ........ A-2
61245.001L7-5A
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
E220/220 T1 HTU-C
HDSL Transceiver Unit -- Central Office
INSTALLATION/MAINTENANCE
Section 61245001L7-5, Issue 1
Figure 1. ADTRAN HTU-C
1. GENERAL
The ADTRAN E220/220 Low Voltage HDSL Transceiver
Unit for the Central Office (HTU-C), part number
1245001L7, is the Central Office (CO) unit used to
deploy an HDSL T1 circuit using four-wire metallic
facilities. The unit occupies one slot in a standard 220
Office Repeater Bay or the ADTRAN E220 Shelf. Figure
1 is an illustration of the ADTRAN HTU-C.
DSX-1 signals are provided to and received from the
network while 2B1Q HDSL signals are provided to the
local loop. The ADTRAN HTU-C works in conjunction
with the ADTRAN HTU-R and HRE to provide a DS1
service up to 24,000 feet on the local loop.
Section 61245001L7-5
Issue 1, May 1998
CLEI Code #T1L2BUCBAA
H T U - C
1 L 7
1 2 4 5 0 0
13 3
0
26 6
E X T
D S X -1
39 9
LB O
53 3
A M I
U FR M
B 8Z S
FR M
S F
E S F
E N
D IS
E N
N IU LB
T D IS
M E O U
LB K TI
L P 1
T X
L P 2
E
Q
R X
D S X
A L M
L B K
R
S
2
3
2
1

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN E220/220

  • Page 1: Table Of Contents

    Table A-1. HDSL Enhanced Loopback Control local loop. The ADTRAN HTU-C works in conjunction Codes ............A-1 with the ADTRAN HTU-R and HRE to provide a DS1 Table A-2. Inband Addressable Loopback Codes ..A-2 service up to 24,000 feet on the local loop.
  • Page 2: Installation

    Kentrox T-Term 220, Wescom 34220 and 34230, Lynch The HDSL local loop operates as two independent 303MA30 as well as the ADTRAN E220 Shelf and the subsystems each operating over a single twisted pair. ADTRAN E220 RP Shelf. No installation wiring is required.
  • Page 3 Disabled Loopback Timeout is Disabled. SW1-2 NIU Loopback This switch programs the ADTRAN HDSL system to respond to traditional T1 network interface Enabled unit (NIU) loop-up and loop-down codes. See Appendix A for more information on specific codes. Disabled SW1-3 Manual Frame Select Selects Superframe (SF) format.
  • Page 4: Connections

    Loop 1 HDSL Ring (Wire-Wrap) HFAC Alarm Outputs If the HTU-C is operating in an ADTRAN E220 or E220 RP Shelf with an HFAC (P/N 1244051LX or equivalent), Fuse Alarm the HTU-C provides information to the HFAC which is Loop 2 HDSL Tip (Wire-Wrap) used to generate alarms.
  • Page 5: Hdsl System Testing

    When the unit is selected for framing, the addressable loopback codes will only be detected when sent in the The ADTRAN HDSL system provides the ability to appropriate framing mode. When the unit is selected for monitor the status and performance of the DSX-1 signals, unframed, the addressable loopback codes will be DS1 signals, and HDSL loop signals.
  • Page 6: Control Port Operation

    TXD (Transmit Data) saving options are disabled or removed. RXD (Receive Data) When operating the unit in the ADTRAN E220 Shelf with an HFAC (HDSL shelf controller), all remote SGN (Signal Ground) terminal operation must be made through the control port of the shelf controller, not the HTU-C.
  • Page 7 200 kHz. The LOSS measurement is a better indication of the loop’s attenuation of the 2B1Q signal than the changes to determine its operating mode. insertion loss measured at a single frequency. Adtran HDSL can operate on cables with an excess of 30 dB LOSS. 61245.001L7-5A...
  • Page 8 S/N : CLEI: MANF: AT HTU-C AT HTU-R Press “M” to view Main Menu. Figure 7. Introductory Menu Screen ADTRAN HDSL MAIN MENU 1) CURRENT SYSTEM STATUS 2) PERFORMANCE HISTORY 3) ADTRAN INFORMATION 4) LOOPBACK OPTIONS 5) SELF-TEST 6) PROVISIONING 7) TROUBLESHOOTING Choose a screen by pressing the corresponding number._ _ _ _ _...
  • Page 9 HTU-C CURRENT SYSTEM STATUS HTU-R LOOP #1 <NETWORK> LOOP #2 ELAPSED TIME 00:00:09 LOOP #1 <CUSTOMER> LOOP #2 -------------------------- --------------------------- 01 dB 01 dB <- LOSS -> 01 dB 01 dB <- SYNC -> 000/00000 000/00000 <- ES 15M/24H -> 000/00000 000/00000 000/00000...
  • Page 10 PERFORMANCE HISTORY <VIEW 1 - HTU-C DSX-1 RECEIVER> 24 HOUR REGISTERS 15 MINUTE REGISTERS ---ES---SES-- --ES-SES----------ES-SES- 00000 00000 <---CURRENT---> 000 000 -1: ----- ----- <-- --> -1: 000 000 -17: 000 000 -2: ----- ----- -2: 000 000 -18: 000 000 -3: ----- ----- -3: 000 000 -19: 000 000...
  • Page 11 LOOPBACK OPTIONS _____ _____ _____ |HTU-C| |HRE 1| |HTU-R| --->|-----|<=========>| |<=========>|-----|<--- NET| |CUST <---|-----|<=========>| |<=========>|-----|<--- |_____| |_____| |_____| 1) LOOPBACK TO NETWORK AT HTU-C = INACTIVE 2) LOOPBACK TO CUSTOMER AT HTU-C = INACTIVE 3) LOOPBACK TO NETWORK AT HTU-R = INACTIVE 4) LOOPBACK TO CUSTOMER AT HTU-R = INACTIVE 5) LOOPBACK TO NETWORK AT HRE1...
  • Page 12 PROVISIONING ________________________________________________ ______________________ PROVISIONS CURRENT SETTINGS HARDWARE SETTINGS ——————————————————---------------------——— ————————--------- DSX-1 LINE BUILDOUT 0-133 FEET 0-133 FEET DSX-1/DS1 LINE CODE B8ZS B8ZS DSX-1/DS1 FRAMING NIU LOOPBACK ENABLED ENABLED LOOPBACK TIMEOUT 20 MIN 20 MIN DS1 TX LEVEL 0 dB DS0 BLOCKING 00000000 00000000 00000000 CHANNELS “X”...
  • Page 13: Hdsl Deployment Guidelines

    6. HDSL DEPLOYMENT GUIDELINES Loop loss per kft for other wire is summarized in Table E. The ADTRAN HDSL system is designed to provide DS1 Table E. HDSL Loss Values Ω based services over loops designed to comply with (200 kHz cable loss in dB/kft at 135 carrier service area (CSA) guidelines.
  • Page 14: Maintenance

    Table G is a troubleshooting guide for the E220/220 Low 9. PRODUCT SPECIFICATIONS Voltage HTU-C. Product specifications are detailed in Table H. 8. MAINTENANCE 10. WARRANTY AND CUSTOMER SERVICE Table G. Troubleshooting Guide ADTRAN will replace or repair this product within ten...
  • Page 15 DSX-1 Channelization: ........Channels 1-12 on HDSL Loop 1, Channels 13-24 on HDSL Loop 2 Power Tested with the ADTRAN Low-Voltage HRE (P/N 1244.042L1) and the ADTRAN Low Voltage HTU-R (1245.021L1). Total Power: ............-48 VDC @ 180 m A with HTU-R -48 VDC @ 370 m A with HTU-R and HRE HTU-C Power Dissipation: ........
  • Page 16: Appendix Ahdsl Loopbacks

    Appendix A HDSL LOOPBACKS HDSL MAINTENANCE MODES This appendix describes operation of the HDSL system The overwrite method produces periodic control with regard to detection of in-band and ESF facility sequences. However, once per frame, the framing bit data link loopback codes. overwrites one of the bits in the control sequence.
  • Page 17 Table A-2. Inband Addressable Loopback Codes FUNCTION CODE RESPONSE ARM ............... 11000 NIU LOOPBACK ENABLED: The HTU-R will loopup towards the network. (also known No AIS or errors will be sent as a result of this loopback. The HTU-C and as a 2-in-5 HRE will ARM.

Table of Contents