4 Construction characteristics

1
Heat pump.
2
Control panel.
3
Enclosure in embossed ABS.
Steel tank (boiler) enamelled according to UNI
4
standards (capacity: 200; 260 litres).
5
Upper boiler probe.
6
Lower boiler probe.
7
Coolant recharge.
8
Ambient air recirculation fan.
9
Lamination valve.
10
High-efficiency finned evaporator. The quantity
of fluid put into this is regulated by an
appropriate thermostatic valve.
11
Air inlet (
160 mm).
12
Air outlet (
160 mm).
13
Hermetically-sealed rotary compressor.
14
Replaceable magnesium anode.
15
(1.5 kW – 230 W) Electric heating element
16
Condenser pump discharge line.
17
Condenser return.
18
Replaceable magnesium anode.
19
Hot water outlet connection joint (G 1").
20
Recirculation fitting (G ¾").
21
Inlet, coil fitting for solar thermal power system
(G 1"
1/4
; 1 m
2
exchange surface).
22
Condensate drain (G 1/2").
23
Outlet, coil fitting for solar thermal power
system (G 1"
1/4
; 1 m
2
surface).
24
Cold water inlet connection joint (G 1").
25
50 mm polyurethane insulation.
26
Automatic resetting safety pressure switch.
29
Air inlet filter.
30
½"G fitting for probe immersion sleeve
Installation and user manual
13
29
1
4
2
5
6
3
7
12
10
11
8
30
14
19
15
16
22
17
18
25
4
9
26
20
21
23
24