Warning: This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance
with the Instructions Manual, may cause interference with radio communication. It has been tested and found to comply with
the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide
reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in
a residential area is likely to cause interference, in which case, user at their own expense will be required to take whatever
measures may be required to correct the interference. Any unauthorized modification of this equipment may result in the
revocation of the owner's authority to continue its operation.

BEFORE INSTALLATION

The DeltaNet MicroCel Controller ("MicroCel"), shown
in Figure 1, is available in five models:
— R7515A MicroCel
— R7515B MicroCel with Microbridge Airflow Sensor
— RP7515A MicroCel with Electric-Pneumatic
Transducer
AUXILIARY C-NAP
SCREW TERMINALS J7
24V AC
AUXILIARY SCREW
TERMINALS J11
INPUT SIDE
BASEBOARD
A. INPUT BOARD SIDE
1
THESE SCREWS MUST BE TIGHTLY INSERTED TO PROVIDE A GOOD GROUND FOR THE BOARDS.
2
USE THIS SCREW TO GROUND THE MicroCel.
Copyright © 1993 Honeywell Inc. • All Rights Reserved
TERMINAL LABEL
1
CASE
1
TERMINALS
INPUT BOARD
WALL MOD
CONNECTOR J8
24V AC/C-NAP MODULAR
CONNECTOR J9
10 PIN CONNECTOR FOR
ADDITIONAL MODULE, J14
Fig. 1. MicroCel Internal View.
DeltaNet R7515A/B,
RP7515A/B, R7516B
MicroCel
Installation INSTRUCTIONS
— RP7515B MicroCel with Microbridge Airflow
Sensor and Electric-Pneumatic Transducer
— R7516B MicroCel with Microbridge Airflow
Sensor and Integral Damper Actuator
1
OUTPUT
BOARD
24V AC AUXILIARY
SCREW TERMINALS J12
B. OUTPUT BOARD SIDE
Controllers
OUTPUT SIDE
BASEBOARD
TRIAC OUTPUT
SCREW
TERMINALS J6
2
1
GROUND
SCREW
BRACKET
MOUNTING
SCREW (2)
C4359-3
95-6083

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell DeltaNet R7515A

  • Page 1 B. OUTPUT BOARD SIDE THESE SCREWS MUST BE TIGHTLY INSERTED TO PROVIDE A GOOD GROUND FOR THE BOARDS. USE THIS SCREW TO GROUND THE MicroCel. C4359-3 Fig. 1. MicroCel Internal View. Copyright © 1993 Honeywell Inc. • All Rights Reserved 95-6083...
  • Page 2 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS The R7515B and R7516B have a microbridge airflow INSTALLATION sensor but not the base unit board assembly, and are used for remote airflow measurement. Mount the MicroCel in a location that allows clearance for Cases are in three sizes as follows: cover removal, wiring, and servicing.
  • Page 3 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS 3-13/16 (97) 3-13/16 (97) 2-9/16 2-9/16 (65) (65) 1-1/16 1-3/16 (27) (30) ACTUATOR SHAFT POSITION R7516B ONLY 6-3/4 (172) 5-7/16 (138) 7-1/16 6-15/16 (180) (176) 7-15/16 3-11/16 R 1/16 (2) (202) (94) (TYPICAL)
  • Page 4 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS 3-15/16 (100) 3-15/16 (100) 2-11/16 2-11/16 (68) (68) 1-3/16 1-3/8 (30) (35) 6-3/4 (172) 5-7/16 (138) 7-1/16 6-15/16 (180) (176) 7-15/16 (202) 3/8 (10) DIAMETER (TYPICAL) (16) 15/16 (20) (24) 3/16 (5) (TYPICAL)
  • Page 5 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS WARNINGS 90-DEGREE ROTATION 1. Do not mount MicroCel with integral damper 60-DEGREE ROTATION actuator where acid fumes or other corrosive 45-DEGREE ROTATION vapors might contact and corrode metal parts. 2. Do not mount MicroCel with integral damper actuator where there is escaping gas or other explosive vapors.
  • Page 6 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS Install damper actuator with output hub over PIPING damper shaft. Tighten 1/8-in. Allen setscrews (Fig. 5) firmly onto Airflow Pickup (Where Used) damper shaft. Secure MicroCel case to damper housing by screwing four No. 10 thread-forming, not thread-cutting (e.g., Connect the airflow pickup to the two 1/4-in.
  • Page 7 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS 5/32 IN. (4 MM) 1/4 IN. (6MM) TUBING MAIN AIR TUBING BRANCH B BRANCH A CAPACITY RELAY SOLENOID FILTER PNEU "A" PNEU "B" CCT1612B 1/4 X 1/4 IN. TEE CAUTION TRIM END OF TUBING EACH TIME IT IS REINSTALLED (TO REMOVE ) (STRETCHED MATERIAL) IF AMBIENT TEMPERATURE IS GREATER THAN 95˚F,...
  • Page 8 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS 8 IN. (200 MM) LEAVE OPEN SECTION SLIT FLAT SIDE OF ELECTRICAL JACKET OF ELECTRICAL TO ACT AS STRAIN RELIEF ELECTRICAL JACKET (SIDE WITH JACKET PAPER MARKER) YELLOW YELLOW CURVED BLACK BLACK SIDE...
  • Page 9 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS Connections Using AK3702R or AK3744 Bus Cable and Optionally AK3326 T-Tap Cable Assembly AK3702R OR AK3744 BUS CABLE YELLOW When using the AK3702R or AK3744 Bus Cable, pull the YELLOW CLASS II cable to each MicroCel on the bus, and connect to Jack J9 TRANSFORMER using AK3326 T-Tap Cable Assembly (Fig.
  • Page 10 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS Wiring Details Figure 16 shows the terminal arrangement in the MicroCel. All MicroCel models are furnished with a terminal arrangement similar to that shown in Figure 16A. The two-input-board R7515A has the additional terminals shown in Figure 16B.
  • Page 11 DELTANET R7515A/B, RP7515A/B, R7516B MICROCEL ™ CONTROLLERS Figure 17 shows a typical wiring diagram. Refer to job drawings for specific wiring diagrams. M-POT COMMUNICATION CABLE CCT2190 M-Cel PORTABLE T7515 M-Cel SPACE OPERATOR TEMPERATURE TO POWER AND C-NAP TERMINAL TEMPERATURE SENSOR...
  • Page 12 Home and Building Control Home and Building Control Honeywell Inc. Honeywell Limited-Honeywell Limitée Honeywell Plaza 155 Gordon Baker Road P.O. Box 524 North York, Ontario Minneapolis, MN 55408-0524 M2H 3N7 95-6083 Rev. 2-93 Printed in U.S.A.

Table of Contents