To Operate The User Interface; Before Operation; To Mount The User Interface Holder; To Insert The Batteries - Daikin ATXF25A5V1BB Operation Manual

Room air conditioner
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

3 Before operation

Icon
2.2.3

To operate the user interface

a
a
Signal receiver
1 Aim the signal transmitter at the signal receiver on the indoor
unit (maximum distance for communication is 7 m).
Result: When the indoor unit receives a signal from the user
interface, you will hear a sound:
Sound
Beep-beep
Beep
Long beep
3
Before operation
3.1

To mount the user interface holder

a
b
c
a
User interface
b
Screws (field supply)
c
User interface holder
1 Choose a place where the signals reach the unit.
2 Attach the holder with screws to the wall or a similar location.
Operation manual
4
Description
Airflow rate = High
Airflow rate = Medium high
Airflow rate = Medium
Airflow rate = Medium low
Airflow rate = Low
Comfort operation is active
Auto vertical swing is active
ON timer is active
OFF timer is active
Description
Operation starts.
Setting changes.
Operation stops.
3 Hang the user interface on the user interface holder.
3.2

To insert the batteries

The batteries will last for about 1 year.
1 Remove the back cover.
2 Insert both batteries at once.
3 Put the cover back.
2
1
AAA.LR03
3.3

To turn on the power supply

1 Turn the circuit breaker on.
Result: The flap of the indoor unit will open and close to set the
reference position.
4

Operation

4.1

Operation range

Operation mode
(a)(b)
Cooling
▪ Outdoor temperature: –10~46°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
(a)
Heating
▪ Outdoor temperature: –15~24°C DB
▪ Indoor temperature: 10~30°C DB
(a)
Drying
▪ Outdoor temperature: –10~46°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
(a)
A safety device might stop the operation of the system if the unit
runs outside its operation range.
(b)
Condensation and water dripping might occur if the unit runs
outside its operation range.
4.2

When to use which feature

You can use the following table to determine which features to use:
Feature
Basic features
To start/stop the system and to set the
Operation modes and
temperature:
temperature
▪ Heat up or cool down a room.
▪ Blow air in a room without heating or
cooling.
▪ Decrease the humidity in a room.
▪ In Automatic mode, automatically
select an appropriate temperature
and operation mode.
To adjust the airflow direction (swing or
Airflow direction
fixed position).
3
Operation range
Tasks
ATXF25~35A5V1B
Daikin room air conditioner
3P520336-8D – 2019.02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Atxf35a5v1bb

Table of Contents