Operational Modes

Below is a list of the phone's different operational modes:
1 Power Off mode
2 Normal Mode (Power controlled by cellular SW, includes various Active and Idle
states):
• Analog Modes (800 MHz only):
•Analog Control Channel, ACCH
•Analog Voice Channel, AVCH
• Digital Modes (800):
•Control Channel, DCCH
•Digital Voice Channel, DTCH (Digital Traffic Channel)
•Digital Data Channel, DDCH
Both the analog and digital modes have different states controlled by the Cellular
SW. Some examples are Idle State (on ACCH), Camping (on DCCH), Scanning, Con-
versation, NSPS (No Service Power Save, previously OOR = Out of Range).
3 Local mode (both Cellular SW and UI SW non active)
4 Test mode (Cellular SW active but UI SW non active)

Environmental Specifications

Normal and extreme voltages

Voltage range:
• nominal battery voltage: 3.6 V
• maximum battery voltage: 5.0 V
• minimum battery voltage: 3.1 V

Temperature Conditions

Temperature range:
• ambient temperature: -30...+ 60 ×C
• PWB temperature: -30...+85 ×C
Page 8
Nokia Corporation
CCS Technical Documentation
Issue 1 02/03