3.4.
Repair Documentation:
3.4.1.
Description of procedure:
3.4.1.1. Diagnosis:
Visually check the status of the Battery connector. Watch for oxidation and dry solder joints.
3.4.1.2. Repair by component change:
Use hot air blower remove defective Battery connector.
Avoid excessive heat!
Watch surrounding components!
Resolder new Battery connector afterwards.
3.4.1.3. Repair by Software booting:
Not possible!
3.4.1.4. Test:
Retest handset after repair.
3.4.2.
List of needed material:
3.4.2.1. Components:
Battery Connector SX1
Placement: X2181
Part-Number: L36334-Z97-C160
3.4.2.2. Jigs and Tools:
Hot Air Blower
Soldering Iron
V 1.0