11.4. Repair Documentation:
11.4.1. Description of procedure:
11.4.1.1.
Diagnosis:
Use the diode test function of a multimeter to check the status of the diode. The typical
voltage drop on the diode is 1.7V when testing the diode function with the
multimeter
11.4.1.2.
Repair by component change:
Use soldering iron to remove defective diode.
Avoid excessive heat!
Watch surrounding components!!
Resolder new diode afterwards.
11.4.1.3.
Resolder new diode afterwards. Repair by Software booting:
Not possible!
11.4.1.4.
Test:
Retest handset after repair.
11.4.2. List of needed material:
11.4.2.1.
Components:
Keyboard LEDs SX1
Placement: V1200. V1201. V1202. V1203
Part-Number: L36840-L2082-D670
11.4.2.2.
Jigs and Tools:
Hot Air Blower
Soldering Iron