Can't turn on:
Check Camera damage or not
Check camera module assembly
I2C interface working normally (you could verify this by LCD
backlight level adjustment or turn on VGA camera)
Check camera power when turn on ( R178_1.8V, R751_2.8V,
R752_2.6V )
Check camera reset pin (R755) signal should pull high after turn on
camera
AF no function:
Check S7 SMT
Check S7_pin3 signal from 2.6V to GND when you press the
capture key to the half.
Check camera module AF pad short with shielding case or not.
Capture key no function:
Check S7 SMT
Check S7_pin1 signal from 2.6V to GND when you press the
capture key.
Service Engineeing & Optimization
Level 3 , Rev.1.0
Can't Take Picture

Advertisement