7
VENTILATION SYSTEM
C. Vertical ventilation system
Step 1 & 2
A-1 Ventilation motor. See Section B, steps 1
and 2 for access to the blower motor. Also see
Figure 8.
Step 3
• Turn the blower unit so that the fan blade open-
ings are facing upward. See Figure 14.
Fan blade openings facing up
After turning
Figure 14
Step 4
• Place the blower unit into the opening. Secure
the case blow fan top, the blower motor and
cover to the microwave oven with the screw (1,
2 and 3) from steps 1 and 2. See Figure 15.
Figure 15
• Carefully match the exhaust opening location
Over The Range Microwave Oven / Installation Manual
• Ensure that the damper hinge is on the front
Back of oven
of the microwave and attach the damper to
blower motor cover by sliding it into the guides
at the blower motor cover. See Figures 16, 17.
and the damper swings free into the wall outlet.
Figure 16
Figure 17
11 / 29 EN