Tubular Stand Mounting; Angle Bracket Mounting - Hatco Glo-Ray Infra-Black GRAIH Series Installation And Operating Manual

Strip heaters
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

Tubular Stand Mounting

Mounting a unit with non-adjustable tubular stands permanently
attaches the unit to a countertop or serving table.
Ensure safe and proper operation. Refer to the "Minimum
Clearance Requirements" listed in the INSTALLATION
section of this manual.
Tubular stands are available in aluminum, Designer colors,
or gloss finishes in heights of 4" to 14" (102 to 356 mm) in
2" (51 mm) increments.
NOTE: Tubular stands cannot be retrofitted in the field.
1. Position the unit upside-down on a flat surface.
NOTE: Units for this application are supplied with the conduit
attached to one side of the unit. Conduit should not be
removed.
2. Secure the top of the tubular stand to the bottom of the
angled end bracket using the screws supplied.
3. Secure the angled end bracket to the end plate of the unit
with the previously removed hanger tab screws.
4. Repeat steps 2 and 3 on the opposite end of the unit.
5. Secure the stands to the mounting surface using
appropriate fasteners.
NOTE: Two pairs of tubular stands will be needed for mounting
dual units.
End Bracket
Screws
Angled
End Bracket
Tubular Stand Mounting
CAUTION
Tubular Stand
Screws
Tubular
Stand

Angle Bracket Mounting

Mounting a unit with an angle bracket permanently attaches
the unit to the underside of a shelf. It can be mounted to a flat
shelf or a shelf with rolled/flanged edges. The adjustable angle
brackets will provide the necessary gap between the unit and
a combustible shelf.
If the shelf has a rolled or flanged edge, use the optional
adjustable angle brackets to mount the unit below the lowest
part of the rolled or flanged edge of the shelf (a minimum gap
of 1" [25 mm] is required between the unit and the underside
of a rolled or flanged edge of the shelf to prevent heat damage
to the electrical system of the unit).
Ensure safe and proper operation. Refer to the "Minimum
Clearance Requirements" listed in the INSTALLATION
section of this manual.
NOTE: When mounting the unit under a shelf, it is
recommended to use a remote control enclosure.
Shelf with 3/4" (19 mm)
flanged edge
Adjustable
Angle
Bracket
Flanged Edge Shelf Installation
1. Position the unit on a flat surface with the heating element
facing down.
2. Remove the two hanger tab screws and hanger tabs.
These items will not be needed.
3. Remove the two upper end plate screws.
4. Align the adjustable angle bracket to the end plate
mounting holes of the unit. Secure angle bracket with
previously removed end plate screws.
Removed
Hanger Tabs
and Screws
End Plate
Screws
Adjustable
Angle Bracket
Adjustable Angle Bracket Installation
12
English
CAUTION
1" (25 mm)
Gap
Minimum
Form No. GRAIHM-0920