Delivery Inspection & Unpacking; Electrical Requirements - FWE AirScreen Series Operating Instructions Manual

Table of Contents

Advertisement

FWE
REFRIGERATED "AIRSCREEN" SERIES
DELIVERY INSPECTION & UNPACKING
DELIVERY INSPECTION
1.
FWE cannot assume responsibility for loss or damage suffered in transit. The carrier assumed full
responsibility of delivery in good order when the shipment was accepted.
2.
All units are factory tested for performance then carefully packaged and certified free from defects
when shipped.
3.
Inspect the packaging for external damage when received. If damage is found follow FWE's policy
on damaged goods outlined below:
FWE's policy on damaged goods:
1.
VISIBLE DAMAGE (Packaging has visible damage when received):
A. Receiver should not accept delivery of the unit.
B. Receiver should sign the bill of lading and clearly indicate which merchandise is being
"refused due to damage".
2.
CONCEALED DAMAGE (Unit has damage that could not be detected until the packaging
was removed):
A. Receiving should inspect the unit for concealed damage inside and out as soon after
delivery as possible.
B. If damage is discovered:
1.
Save all packaging materials for inspection.
2.
Immediately inform your dealer and trucking company. Receiver must call the carrier
to schedule an inspection of the damaged unit within 15 days.
3.
Contact FWE customer service at 800-222-4393 to alert them of the situation.
4.
Under no circumstances may a damaged unit be returned to FWE without a prior
written factory Return Merchandise Authorization (RMA).
UNPACKING
1.
Your AirScreen refrigerator is shipped from the factory on a wood pallet and packaged in a durable
cardboard carton. The carton is constructed using large staples and attached to the pallet using poly
strapping. Remove all the staples prior to removing the carton to avoid scratching the unit
2.
After removing the strapping material the unit can be carefully removed from the pallet.
3.
FWE does not recommend laying the unit down horizontally on its front, sides or back. If the unit has
been laid down horizontally it must be allowed to remain upright for a minimum of 48 hours before
plugging in and turning on. This insures that the compressor oils and refrigerant settle and avoid
damage to the refrigeration components when turned on.
4.
Remove tray slides and all packaging from inside the unit.
4
FWE Operating Instructions | Refrigerated "AirScreen" Series
FWE
REFRIGERATED "AIRSCREEN" SERIES

ELECTRICAL REQUIREMENTS

1.
Check the serial plate for the voltage of the
unit and insure the electrical outlet provided
matches the voltage of the unit.
See the electrical specifications chart to the
right:
2. WARNING:
The supply voltage must be
checked by a qualified electrician with a full
knowledge of all electrical codes. Improper
installation can result in personal injury and
property damage. Prior to connection be
certain that the voltage of the unit is correct
(refer to serial tag for correct unit voltage).
If the unit is 120V use a dedicated 15 Amp
circuit with a 5-15R receptacle. If the unit is
220-240 use a dedicated 15 Amp circuit with
a 6-15R receptacle. Wire to the outlet must
be sized correctly to handle the load.
3. WARNING:
For your safety and protection, all units are supplied with a 10 foot power
cord with a 3 prong grounded plug. Unit must be plugged into a properly grounded outlet.
Do not under any circumstances cut or remove the round grounding prong from the plug,
or use an extension cord.
4.
There is a wiring diagram in the back of this manual for technical reference, however
if service is required contact FWE Customer Service and provide the model and serial
number of the unit.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE GROUNDING PRONG FROM THE CORD PLUG.
ONLY A QUALIFIED ELECTRICIAN OR SERVICE TECHNICIAN
SHOULD ATTEMPT TO REPAIR OR REPLACE ELECTRICAL
COMPONENTS OR WIRING.
SHOCK HAZARD
To Avoid Electric Shock Disconnect power before servicing,
NOTICE
moving or cleaning unit.
ELECTRICAL REQUIREMENTS
5

Hide quick links: