Problems
Thermostat is hot.
Displayed temperature
is incorrect.
The thermostat
displays LP instead of
the temperature.
The screen is blank.
Table 1. In case of difficulty
This is normal. Ensure that the heater capacity does not
exceed the thermostat's maximum load. Keep thermostat air
vents clean and unobstructed at all times.
Remediate if any the following conditions exists:
The thermostat is exposed to air draft.
The thermostat is located near or above a heat source such as
a light dimmer.
The thermostat is currently without power. This can happen in
either condition:
There is a power outage.
The thermal protection device on the heater is opened. This
can happen if the heater is obstructed by furniture or curtain
and has overheated, or if the heater's thermal protection
device is too sensitive.
LP appears for the first five minutes. Then the screen becomes
blank.
Solutions