(4) Hold the lever and pull the serviceplug straight up.
6) After removing the service plug, leave it for 10 min.
7) Wear insulating gloves and measure the voltage at the high voltage cable connection
(junction box side) using the following procedure.
(1) Remove the seal cover.
Caution
• Be careful not to allow foreign matter or water dropets to enter the junction box
Since the junction box has a high voltage circuit, there is a risk of malfunction
if foreign matter or water drops enter it.
15