RS-232 and IR
Figure 7 shows how to wire the Control (RS-232 and IR) connector.
CONTROL
Figure 7.
NOTE: The IR Tx and Rx line pair and the RS-232 Tx and Rx line pair must each cross
once between this connector and the source or destination.

TP Cable Termination and Recommendations

It is vital that your Ethernet cable be the correct cable type and that it be properly terminated
with the correct pinout. Ethernet links use Category (CAT) 3, 5e, or CAT 6, unshielded
twisted pair (UTP) or shielded twisted pair (STP) cables, terminated with RJ-45 connectors.
Ethernet cables are limited to a length of 328 feet (100 meters).
NOTES:
Do not use standard telephone cables. Telephone cables do not support Ethernet
or Fast Ethernet.
Do not stretch or bend cables. Transmission errors can occur.
The cable used depends on your network speed. The unit supports
10 Mbps (10Base-T — Ethernet), 100 Mbps (100Base-T — Fast Ethernet), and
1000 Mbps (1000Base-T — IEEE 802.3ab) half-duplex and full-duplex Ethernet
connections.
10Base-T Ethernet requires CAT 3 UTP or STP cable at minimum.
100Base-T Fast Ethernet requires CAT 5e UTP or STP cable at minimum.
1000Base-T Gigabit Ethernet requires CAT 5, CAT 5e, CAT 6, or CAT 7 UTP or STP
cable.
The Ethernet cable must be terminated as a patch (straight-through) cable and must be
properly terminated in accordance with the TIA/EIA T568-B wiring standard (see figure 8).
Side
Figure 8.
IR Device
Rx
Tx
Gnd
Tx
Rx
Gnd
RS-232 Device
Control and Sync Connectors Wiring
Pins:
RJ-45
1 2 3 4 5 6 7 8
Connector
TIA/EIA T
568 B
Pin
Wire color
1
White-orange
Orange
2
3
White-green
4
Blue
5
White-blue
6
Green
Insert
7
White-brown
Twisted
8
Brown
Pair Wires
RJ-45 Connector and Pinout Tables
FOX3 T 201 Transmitter • Installation and Operation
11